Ai339
2. Electrical Specification
2.1 Operating Voltage Conditions
Symbol
Operating conditions
Typ.
Unit
Notes
Max.
Min.
VDD
PT
12.0
- 6.0
0.0
12.5
- 5.5
V
V
V
11.5
- 6.5
‒
GND
‒
3.3
3.6
H - L
3.0
ΦRG
V
V
V
*1
*2
*3
Bias
( Internal bias )
18.0
19.0
H - L
17.0
ΦSUB
Bias
( Internal bias )
3.3
0.0
3.6
0.2
H
3.0
ΦH1, ΦH2
L
- 0.2
11.5
- 0.2
- 6.5
- 0.2
- 6.5
12.0
0.0
12.5
0.2
H
ΦV1
V
V
M
L
- 6.0
0.0
- 5.5
0.2
*4
M
L
ΦV2, ΦV3, ΦV4
- 6.0
- 5.5
Note) Driving voltage value of the above table indicates the voltage value in each Pad of the image sensor.
Note) *1 : Reset gate (ΦRG )
Note) *2 : Substrate (ΦSUB )
Note) *4 : Horizontal (ΦH1, ΦH2 )
Note) *4 : Vertical ( ΦV1 toΦV4 )
A1 PROs Co., Ltd.
Professional Promotion Process Profit
4