Ai339
3.3.4. Vertical transfer efficiency
1) Set 1.0 lx illumination condition, then measure the signal output.
2) Detect average value of horizontal last line in effective area ( V_EFF ).
3) Detect average value of horizontal first line in OB area ( V_OB ).
4) Detect average value of horizontal line in reference area ( V_REF ).
5) Detect Vertical transfer efficiency with the following formula
6) See figure 3 below for the Test area.
3.3.5. Horizontal transfer efficiency
1) Set 1.0 lx illumination condition, then measure the signal output.
2) Detect average value of vertical last line in effective area ( H_EFF ).
3) Detect average value of vertical first line in OB area ( H_OB ).
4) Detect average value of vertical line in reference area ( H_REF ).
5) Detect Horizontal transfer efficiency with the following formula
6) See figure 4 below for the Test area.
A1 PROs Co., Ltd.