WS74HC595
ABSOLUTE MAXIMUM RATINGS
Parameter
Value
Unit
DC supply voltage Vcc
- 0.5 ~ + 7.0
V
DC input clamp current Iik (Vi<0 or Vi>Vcc)
±20
mA
DC output clamp current Iok (Vo<0 or Vo>Vcc)
±20
mA
DC Current Drain per pin, any output (I
out
)
±35
mA
DC supply Current, Vcc or GND (Icc)
±70
mA
Storage Temperature( T
STG
)
-65 ~ +150
℃
Lead Temperature(T
L
) (Soldering, 10seconds)
260
℃
Note:
1. Absolute maximum ratings are those values beyond which the safety of the device cannot be guaranteed.
RECOMMENDED OPERATING CONDITONS
Parameter
Power Supply Voltage (Vcc)
VCC=2.0V
Min.
Normal
Max.
Unit
2
VCC=4.5V
5
6
V
V
IH
High-level
input voltage
VCC=6.0V
1.5
3.15
4.2
V
VCC=2.0V
V
IL
Low-level
Input Voltage
VCC=4.5V
VCC=6.0V
0.5
1.35
1.8
V
V
I
Input Voltage
V
O
Output Voltage
Operating Temperature (TA)
74HC595
0
0
-40
Vcc
Vcc
85
V
V
℃
Input Rise/Fall Times (tr, tf)
VCC=2.0V
VCC=4.5V
VCC=6.0V
1000
500
400
ns
Note
:
2. All unused inputs of the device must be held at Vcc or GND to ensure proper device operation.
3. If this device is used in the threshold region (from V
IL
max = 0.5 V to V
IH
min = 1.5 V), there is a
potential to go into the wrong state from induced grounding, causing double clocking. Operating
with the inputs at t
t
= 1000 ns and Vcc = 2 V does not damage the device; however, functionally, the
CLK inputs are not ensured while in the shift, count, or toggle operating modes.