HV300/HV310  
Typical Application Circuit  
Long  
Pin  
GND  
Jumper  
8
Short  
Pin  
V
DD  
GND  
PWRGD  
1
R1  
487kΩ  
ENABLE  
3
2
UV  
OV  
+5V  
HV300LG or  
HV310LG  
R2  
6.81kΩ  
Cload  
DC/DC  
PWM  
CONVERTER  
COM  
R3  
9.76kΩ  
RAMP  
V
EE  
SENSE  
GATE  
7
4
5
6
NOTES: 1. Undervoltage Lockout (UV) set to 35V  
2. Overvoltage Lockout (OV) set to 65V  
3. Remove Jumper if Short Pin is used  
C1  
10nF  
Long  
Pin  
-48V  
R4  
50mΩ  
Q1  
IRF530  
UVoff = 1.16 = 35 * (R2 + R3) / 500K  
R2 = (1.16 * 500K) / 35 – 9.76k= 6.81k.  
The closest 1% value is 6.81k.  
Application Information  
Under Voltage and Over Voltage Detection  
The UV and OV pins are connected to comparators with nominal  
1.21V thresholds and 100mV of hysteresis (1.21V ± 50mV).  
They are used to detect under voltage and over voltage  
conditions at the input to the circuit. Whenever the OV pin rises  
above its threshold or the UV pin falls below its threshold the  
GATE voltage is immediately pulled low, the PWRGD signal is  
deactivated and the external capacitor connected to the RAMP  
pin is discharged.  
Then R1 = 500K – (R2 +R3) = 483kΩ  
The closest 1% value is 487k.  
The under voltage and over voltage trip points can be  
programmed by means of the three resistor divider formed by  
R1, R2 and R3. Since the input currents on the UV and OV pins  
are negligible the resistor values may be calculated as follows:  
Undervoltage/Overvoltage Operation  
GND  
UV  
OFF  
UV  
ON  
VIN  
UVoff = VUVH = 1.16 = |VEEUV| * (R2+R3) / (R1+R2+R3)  
OVoff = VOVL = 1.26 = |VEEOV| * R3 / (R1+R2+R3)  
OV  
ON  
OV  
OFF  
Where |VEEUV| and |VEEOV| are Under & Over Voltage Set  
points.  
ON  
Pass  
Transistor  
OFF  
If we select a divider current of 100µA at a nominal operating  
input voltage of 50 Volts then  
(R1+R2+R3) = 50V / 100µA = 500kΩ  
Current Limit  
From the second equation for an Over voltage set point of 65  
Volts the value of R3 may be calculated.  
The current limit magnitude above which the current will not be  
allowed to rise during startup is programmed using a sense  
resistor connected from the SENSE pin to VEE pin. For example  
to program a current limit of 1A, one would choose a resistor as  
follows:  
OVoff = 1.26 = 65 * R3 / 500kΩ  
R3 = (1.26 * 500K) / 65 = 9.69 kΩ  
The closest 1% value is 9.76k.  
Rsense = 50mV / Isense  
Rsense = 50mV / 1A  
Rsense = 50mΩ  
From the first equation for an Under Voltage set point of 35  
Volts the value R2 can be calculated.  