FM24C64C  
Figure 3. Data Transfer Protocol  
Stop Condition  
The receiver could fail to acknowledge for two  
distinct reasons. First, if a byte transfer fails, the No-  
Acknowledge ends the current operation so that the  
device can be addressed again. This allows the last  
A Stop condition is indicated when the bus master  
drives SDA from low to high while the SCL signal is  
high. All operations must end with a Stop condition.  
If an operation is pending when a stop is asserted, the  
operation will be aborted. The master must have  
control of SDA (not a memory read) in order to assert  
a Stop condition.  
byte to be recovered in the event of  
a
communication error. Second and most common,  
the receiver does not acknowledge the data to  
deliberately end an operation. For example, during a  
read operation, the FM24C64C will continue to  
place data onto the bus as long as the receiver sends  
acknowledges (and clocks). When a read operation  
is complete and no more data is needed, the receiver  
must not acknowledge the last byte. If the receiver  
acknowledges the last byte, this will cause the  
FM24C64C to attempt to drive the bus on the next  
clock while the master is sending a new command  
such as a Stop command.  
Start Condition  
A Start condition is indicated when the bus master  
drives SDA from high to low while the SCL signal is  
high. All read and write transactions begin with a  
Start condition. An operation in progress can be  
aborted by asserting a Start condition at any time.  
Aborting an operation using the Start condition will  
ready the FM24C64C for a new operation.  
Slave Address  
If during operation the power supply drops below the  
specified VDD minimum, the system should issue a  
Start condition prior to performing another operation  
The first byte that the FM24C64C expects after a  
start condition is the slave address. As shown in  
Figure 4, the slave address contains the Slave ID  
(device type), the device select address bits, and a  
bit that specifies if the transaction is a read or a  
write. Bits 7-4 define the device type and must be  
set to 1010b for the FM24C64C. These bits allow  
other types of function types to reside on the 2-wire  
bus within an identical address range. Bits 3-1 are  
the select bits which are equivalent to chip select  
bits. They must match the corresponding value on  
the external address pins to select the device. Up to  
eight FM24C64Cs can reside on the same two-wire  
bus by assigning a different address to each. Bit 0 is  
the read/write bit. A 1 indicates a read operation,  
and a 0 indicates a write.  
Data/Address Transfer  
All data transfers (including addresses) take place  
while the SCL signal is high. Except under the two  
conditions described above, the SDA signal should  
not change while SCL is high.  
Acknowledge  
The Acknowledge takes place after the 8th data bit  
has been transferred in any transaction. During this  
state the transmitter should release the SDA bus to  
allow the receiver to drive it. The receiver drives the  
SDA signal low to acknowledge receipt of the byte.  
If the receiver does not drive SDA low, the condition  
is a No-Acknowledge and the operation is aborted.  
Rev. 1.1  
June 2011  
4 of 12