PBL 402 15
Operating conditions:
Parameter
Condition
Symbol
Min.
Typ.
Max.
Unit
Temperature range
Fully compliant
Operational
TAMB
-20
-40
2.7
70
85
4.5
2
°C
Supply voltage range
Shutdown supply current
Supply current
Stand-by turn on time (a)
Receive turn on time (b)
Transmit turn on time (b)
Vcc
IOFF
IACTIVE
τON
τRXON
τTXON
V
µA
mA
µs
µs
µs
One slot duplex communication
6
3
3
3
a. Time may depend upon settling time of the limiting strip DC correction feedback.
b. Time for the receive or transmit gain to be within 1 dB of its final value.
57mA
51mA
Typical current consumption
17mA
Tx
19mA
Rx
t
Receive, 1 slot
10 slots
Transmit, 1 slot
Setup to transmit, (blind slot)
Setup to receive, (blind slot)
Figure 7. Typical current consumtion.
Digital I/O Parameters
The digital output PA_GATE is served of the VCCRF/GndRF supply. All other digital signals are served of the VCCPLL/GndPLL
supply. The digital signals are EN, RXEN,TXEN, ST, D, CK, GATE, LD, MOD and SHOLD.
Parameter
Condition
Symbol
Min.
Typ.
Max.
Unit
Input voltage high
Input voltage low
VIH
VIL
2.1
V
V
0.6
Output voltage high
Output voltage low
Digital input capacitance
Digital input resistance
Digital load capacitance
Digital load resistance
VOH
VOL
CDI
RDI
CDL
RDL
VCC-0.4 VCC-0.2
V
V
pF
kΩ
pF
kΩ
0.6
2
100
30
4
8