Typical Performance
25
90
80
70
60
50
40
30
20
10
0
Conditions:
TJ ≤ 150 °C
Conditions:
TJ ≤ 150 °C
20
15
10
5
0
-55
-30
-5
20
45
70
95
120
145
-55
-30
-5
20
45
70
95
120
145
Case Temperature, TC (°C)
Case Temperature, TC (°C)
Figure 19. Continuous Drain Current Derating vs.
Case Temperature
Figure 20. Maximum Power Dissipation Derating vs.
Case Temperature
1
0.5
0.3
10 µs
Limited by RDS On
100 µs
10.00
1 ms
0.1
100E-3
100 ms
0.05
1.00
0.10
0.01
0.02
0.01
10E-3
1E-3
SinglePulse
Conditions:
TC = 25 °C
D = 0,
Parameter: tp
0.1
1
10
100
1000
1E-6
10E-6
100E-6
1E-3
10E-3
100E-3
1
Drain-Source Voltage, VDS (V)
Time, tp (s)
Figure 21. Transient Thermal Impedance
(Junction - Case)
Figure 22. Safe Operating Area
200
160
120
80
120
Conditions:
TJ = 25 °C
Conditions:
TJ = 25 °C
V
R
V
DD = 600 V
G(ext) = 2.5 Ω
GS = -4V/+15 V
V
R
V
DD = 400 V
G(ext) = 2.5 Ω
GS = -4V/+15 V
100
80
60
40
20
0
ETotal
FWD = C3M0120090J
L = 142 μH
FWD = C3M0120090J
L = 142 μH
ETotal
EOn
EOn
EOff
EOff
40
0
0
5
10
15
20
25
0
5
10
15
20
25
Drain to Source Current,IDS (A)
Drain to Source Current,IDS (A)
Figure 23. Clamped Inductive Switching Energy vs.
Drain Current (VDD = 600V)
Figure 24. Clamped Inductive Switching Energy vs.
Drain Current (VDD = 400V)
6
C3M0120090J Rev. - , 12-2015