 浏览型号5962-0422102QZA的Datasheet PDF文件第4页浏览型号5962-0422102QZA的Datasheet PDF文件第5页浏览型号5962-0422102QZA的Datasheet PDF文件第6页浏览型号5962-0422102QZA的Datasheet PDF文件第7页浏览型号5962-0422102QZA的Datasheet PDF文件第9页浏览型号5962-0422102QZA的Datasheet PDF文件第10页浏览型号5962-0422102QZA的Datasheet PDF文件第11页浏览型号5962-0422102QZA的Datasheet PDF文件第12页  
3.11 Processing options. Since the device is capable of being programmed by either the manufacturer or the user to result in  
a wide variety of configurations; two processing options are provided for selection in the contract.  
3.11.1 Unprogrammed device delivered to the user. All testing shall be verified through group A testing as defined in 4.4.1  
and table IIA.  
3.11.2 Manufacturer-programmed device delivered to the user. All testing requirements and quality assurance provisions  
herein shall be satisfied by the manufacturer prior to delivery. Manufacturer shall verify design checksum after programming.  
4. VERIFICATION  
4.1 Sampling and inspection. For device classes Q and V, sampling and inspection procedures shall be in accordance with  
MIL-PRF-38535 or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan  
shall not affect the form, fit, or function as described herein. For device class M, sampling and inspection procedures shall be in  
accordance with MIL-PRF-38535, appendix A.  
4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted  
on all devices prior to qualification and technology conformance inspection. For device class M, screening shall be in  
accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection.  
4.2.1 Additional criteria for device class M.  
a. Delete the sequence specified as initial (preburn-in) electrical parameters through interim (postburn-in) electrical  
parameters of method 5004 and substitute lines 1 through 6 of table IIA herein.  
b. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made  
available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases,  
and power dissipation, as applicable, in accordance with the intent specified in method 1015.  
(1) Dynamic burn-in for device class M (method 1015 of MIL-STD-883, test condition D; for circuit, see 4.2.1b herein).  
c. Interim and final electrical test parameters shall be as specified in table IIA herein.  
4.2.2 Additional criteria for device classes Q and V.  
a. The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the  
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under  
document revision level control of the device manufacturer's Technology Review Board (TRB) in accordance with MIL-  
PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall  
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in  
method 1015 of MIL-STD-883.  
b. Constant acceleration method 2001 of MIL-STD-883 shall be performed to condition B for devices built with case  
outline X, Y, Z, U, M, T, and N.  
c. Binning program performed prior to burn-in.  
d. Interim and final electrical test parameters shall be as specified in table IIA herein.  
e. Additional screening for device class V beyond the requirements of device class Q shall be as specified in  
MIL-PRF-38535, appendix B.  
f. Additional screening for devices 03, 04, 07, and 08 shall include:  
(1) Internal visual, TM 2010 condition A  
(2) 100% x-ray (top view only)  
(3) 100% PIND (PIND is included for all devices (01 through 08))  
(4) Serialization (Serialization is included for all devices (01 through 08))  
(5) Static Burn-in, delta, read and record, PDA (3% functional)  
SIZE  
STANDARD  
5962-04221  
A
MICROCIRCUIT DRAWING  
DEFENSE SUPPLY CENTER COLUMBUS  
COLUMBUS, OHIO 43218-3990  
REVISION LEVEL  
SHEET  
C
8
DSCC FORM 2234  
APR 97