 浏览型号HD6433846XXXH的Datasheet PDF文件第326页浏览型号HD6433846XXXH的Datasheet PDF文件第327页浏览型号HD6433846XXXH的Datasheet PDF文件第328页浏览型号HD6433846XXXH的Datasheet PDF文件第329页浏览型号HD6433846XXXH的Datasheet PDF文件第331页浏览型号HD6433846XXXH的Datasheet PDF文件第332页浏览型号HD6433846XXXH的Datasheet PDF文件第333页浏览型号HD6433846XXXH的Datasheet PDF文件第334页  
Start  
1. Set bit MPIE to 1 in SCR3.  
Set bit MPIE to 1  
in SCR3  
1
2
2. Read bits OER and FER in the serial  
status register (SSR) to determine if  
there is an error. If a receive error has  
occurred, execute receive error processing.  
Read bits OER  
and FER in SSR  
3. Read SSR and check that bit RDRF is  
set to 1. If it is, read the receive data in  
RDR and compare it with this receiver's  
own ID. If the ID is not this receiver's,  
set bit MPIE to 1 again. When the RDR  
data is read, bit RDRF is cleared to 0  
automatically.  
Yes  
OER + FER = 1?  
No  
Read bit RDRF  
in SSR  
3
4. Read SSR and check that bit RDRF is  
set to 1, then read the data in RDR.  
No  
RDRF = 1?  
Yes  
5. If a receive error has occurred, read bits  
OER and FER in SSR to identify the error,  
and after carrying out the necessary error  
processing, ensure that bits OER and FER  
are both cleared to 0. Reception cannot be  
resumed if either of these bits is set to 1.  
In the case of a framing error, a break can  
be detected by reading the value of the  
RXD3x pin.  
Read receive  
data in RDR  
No  
Own ID?  
Yes  
Read bits OER  
and FER in SSR  
Yes  
OER + FER = 1?  
No  
Read bit RDRF  
in SSR  
4
No  
RDRF = 1?  
Yes  
Read receive  
Receive error  
processing  
data in RDR  
5
Yes  
Continue data  
reception?  
No  
(A)  
Clear bit RE to  
0 in SCR3  
End  
Figure 10-24 Example of Multiprocessor Data Reception Flowchart  