Table 6-4 and table 6-5 give the electrical characteristics in programming mode.
Table 6-4 DC Characteristics
(Conditions: VCC = 6.0 V ±0.25 V, VPP = 12.5 V ±0.3 V, VSS = 0 V, Ta = 25°C ±5°C)
Item
Symbol Min
Typ Max
Unit Test Condition
Input high-
level voltage OE, CE, PGM
EO7 to EO0, EA16 to EA0 VIH
2.4
–0.3
2.4
—
—
—
—
—
—
VCC + 0.3 V
Input low-
level voltage OE, CE, PGM
EO7 to EO0, EA16 to EA0 VIL
0.8
—
V
Output high- EO7 to EO0
level voltage
VOH
VOL
V
IOH = –200 µA
IOL = 0.8 mA
Output low
level voltage
EO7 to EO0
0.45
2
V
Input leakage EO7 to EO0, EA16 to EA0 |ILI|
—
µA
Vin = 5.25 V/0.5 V
current
OE, CE, PGM
VCC current
VPP current
ICC
IPP
—
—
—
—
40
40
mA
mA
124