X51638
CAPACITANCE T = +25°C, f = 1MHz, V
= 5V.
A
CC
Symbol
Test
Max.
Units
pF
Conditions
= 0V
(2)
8
6
V
OUT
Output Capacitance (SO, RESET)
C
OUT
(2)
pF
V
= 0V
Input Capacitance (SCK, SI, CS, WP)
C
IN
IN
Notes: (1) V min. and V max. are for reference only and are not tested.
IL
IH
(2) This parameter is periodically sampled and not 100% tested.
EQUIVALENT A.C. LOAD CIRCUIT AT 5V V
A.C. TEST CONDITIONS
CC
V
x 0.1 to V x 0.9
Input Pulse Levels
CC
CC
5V
5V
Input Rise and Fall Times
Input and Output Timing Level
10ns
3.3KW
1.64KW
V
x 0.5
CC
SO
OUTPUT
RESET
1.64KW
30pF
100pF
11