 浏览型号Z8F082ASH020SC的Datasheet PDF文件第120页浏览型号Z8F082ASH020SC的Datasheet PDF文件第121页浏览型号Z8F082ASH020SC的Datasheet PDF文件第122页浏览型号Z8F082ASH020SC的Datasheet PDF文件第123页浏览型号Z8F082ASH020SC的Datasheet PDF文件第125页浏览型号Z8F082ASH020SC的Datasheet PDF文件第126页浏览型号Z8F082ASH020SC的Datasheet PDF文件第127页浏览型号Z8F082ASH020SC的Datasheet PDF文件第128页  
Z8 Encore! XP® F08xA Series  
Product Specification  
106  
Receiving IrDA Data  
Data received from the infrared transceiver using the IR_RXD signal through the RXD pin  
is decoded by the Infrared Endec and passed to the UART. The UART’s baud rate clock is  
used by the Infrared Endec to generate the demodulated signal (RXD) that drives the  
UART. Each UART/Infrared data bit is 16-clocks wide. Figure 17 illustrates data recep-  
tion. When the Infrared Endec is enabled, the UART’s RXD signal is internal to the Z8  
Encore! XP® F08xA Series products while the IR_RXD signal is received through the  
RXD pin.  
16 clock  
period  
Baud Rate  
Clock  
Start Bit = 0  
Data Bit 0 = 1  
Data Bit 1 = 0  
Data Bit 2 = 1  
Data Bit 3 = 1  
IR_RXD  
min. 1.4µs  
pulse  
UART’s  
RXD  
Start Bit = 0  
Data Bit 0 = 1  
Data Bit 1 = 0  
Data Bit 2 = 1  
Data Bit 3 = 1  
8 clock  
delay  
16 clock  
period  
16 clock  
period  
16 clock  
period  
16 clock  
period  
Figure 17.IrDA Data Reception  
Infrared Data Reception  
The system clock frequency must be at least 1.0MHz to ensure proper reception of the  
Caution:  
1.4µs minimum width pulses allowed by the IrDA standard.  
Endec Receiver Synchronization  
The IrDA receiver uses a local baud rate clock counter (0 to 15 clock periods) to generate  
an input stream for the UART and to create a sampling window for detection of incoming  
pulses. The generated UART input (UART RXD) is delayed by 8 baud rate clock periods  
with respect to the incoming IrDA data stream. When a falling edge in the input data  
stream is detected, the Endec counter is reset. When the count reaches a value of 8, the  
UART RXD value is updated to reflect the value of the decoded data. When the count  
reaches 12 baud clock periods, the sampling window for the next incoming pulse opens.  
The window remains open until the count again reaches 8 (in other words, 24 baud clock  
periods since the previous pulse was detected), giving the Endec a sampling window of  
PS024705-0405  
P R E L I M I N A R Y  
Infrared Encoder/Decoder