 浏览型号Z8F021APH020SC的Datasheet PDF文件第140页浏览型号Z8F021APH020SC的Datasheet PDF文件第141页浏览型号Z8F021APH020SC的Datasheet PDF文件第142页浏览型号Z8F021APH020SC的Datasheet PDF文件第143页浏览型号Z8F021APH020SC的Datasheet PDF文件第145页浏览型号Z8F021APH020SC的Datasheet PDF文件第146页浏览型号Z8F021APH020SC的Datasheet PDF文件第147页浏览型号Z8F021APH020SC的Datasheet PDF文件第148页  
Z8 Encore! XP® 4K Series  
Product Specification  
125  
ANAIN[3:0]—Analog Input Select  
These bits select the analog input for conversion. Not all Port pins in this list are available  
in all packages for the Z8 Encore! XP® 4K Series. Refer to the chapter Pin Description on  
page 7 for information regarding the Port pins available with each package style. Do not  
enable unavailable analog inputs. Usage of these bits changes depending on the buffer  
mode selected in ADC Control/Status Register 1.  
For the reserved values, all input switches are disabled to avoid leakage or other undesir-  
able operation. ADC samples taken with reserved bit settings are undefined.  
SINGLE-ENDED:  
0000 = ANA0 (transimpedance amp output when enabled)  
0001 = ANA1 (transimpedance amp inverting input)  
0010 = ANA2 (transimpedance amp non-inverting input)  
0011 = ANA3  
0100 = ANA4  
0101 = ANA5  
0110 = ANA6  
0111 = ANA7  
1000 = Reserved  
1001 = Reserved  
1010 = Reserved  
1011 = Reserved  
1100 = Hold transimpedance input nodes (ANA1 and ANA2) to ground.  
1101 = Reserved  
1110 = Temperature Sensor.  
1111 = Reserved.  
DIFFERENTIAL (non-inverting input and inverting input respectively):  
0000 = ANA0 and ANA1  
0001 = ANA2 and ANA3  
0010 = ANA4 and ANA5  
0011 = ANA1 and ANA0  
0100 = ANA3 and ANA2  
0101 = ANA5 and ANA4  
0110 = ANA6 and ANA5  
0111 = ANA0 and ANA2  
1000 = ANA0 and ANA3  
1001 = ANA0 and ANA4  
1010 = ANA0 and ANA5  
1011 = Reserved  
1100 = Reserved  
1101 = Reserved  
1110 = Reserved  
1111 = Manual Offset Calibration Mode  
PS022815-0206  
Analog-to-Digital Converter