 浏览型号Z8F021APH020SC的Datasheet PDF文件第120页浏览型号Z8F021APH020SC的Datasheet PDF文件第121页浏览型号Z8F021APH020SC的Datasheet PDF文件第122页浏览型号Z8F021APH020SC的Datasheet PDF文件第123页浏览型号Z8F021APH020SC的Datasheet PDF文件第125页浏览型号Z8F021APH020SC的Datasheet PDF文件第126页浏览型号Z8F021APH020SC的Datasheet PDF文件第127页浏览型号Z8F021APH020SC的Datasheet PDF文件第128页  
Z8 Encore! XP® 4K Series  
Product Specification  
105  
address mismatch occurs.  
11 = The UART generates an interrupt request on all received data bytes for which the  
most recent address byte matched the value in the Address Compare Register.  
MPEN—MULTIPROCESSOR (9-bit) Enable  
This bit is used to enable MULTIPROCESSOR (9-bit) mode.  
0 = Disable MULTIPROCESSOR (9-bit) mode.  
1 = Enable MULTIPROCESSOR (9-bit) mode.  
MPBT—Multiprocessor Bit Transmit  
This bit is applicable only when MULTIPROCESSOR (9-bit) mode is enabled. The 9th bit  
is used by the receiving device to determine if the data byte contains address or data infor-  
mation.  
0 = Send a 0 in the multiprocessor bit location of the data stream (data byte).  
1 = Send a 1 in the multiprocessor bit location of the data stream (address byte).  
DEPOL—Driver Enable Polarity  
0 = DE signal is Active High.  
1 = DE signal is Active Low.  
BRGCTL—Baud Rate Control  
This bit causes an alternate UART behavior depending on the value of the REN bit in the  
UART Control 0 Register.  
When the UART receiver is not enabled (REN=0), this bit determines whether the Baud  
Rate Generator issues interrupts.  
0 = Reads from the Baud Rate High and Low Byte registers return the BRG Reload Value  
1 = The Baud Rate Generator generates a receive interrupt when it counts down to 0.  
Reads from the Baud Rate High and Low Byte registers return the current BRG count  
value.  
When the UART receiver is enabled (REN=1), this bit allows reads from the Baud Rate  
Registers to return the BRG count value instead of the Reload Value.  
0 = Reads from the Baud Rate High and Low Byte registers return the BRG Reload Value.  
1 = Reads from the Baud Rate High and Low Byte registers return the current BRG count  
value. Unlike the Timers, there is no mechanism to latch the Low Byte when the High  
Byte is read.  
RDAIRQ—Receive Data Interrupt Enable  
0 = Received data and receiver errors generates an interrupt request to the Interrupt Con-  
troller.  
1 = Received data does not generate an interrupt request to the Interrupt Controller. Only  
receiver errors generate an interrupt request.  
IREN—Infrared Encoder/Decoder Enable  
0 = Infrared Encoder/Decoder is disabled. UART operates normally.  
1 = Infrared Encoder/Decoder is enabled. The UART transmits and receives data through  
the Infrared Encoder/Decoder.  
PS022815-0206  
UART  