STANDARD TEST CONDITIONS
The previous DC Characteristics and Capacitance sections apply to the
following standard test conditions, unless otherwise noted. All voltages
are referenced to GND (0V). Positive current flows in to the referenced
pin.
All AC parameters assume a load capacitance of 100 pF. Add 10 ns delay
for each 50 pF increase in load up to a maximum of 200 pF for the data
bus and 100 pF for the address and control lines. AC timing
measurements are referenced to 1.5 volts (except for CLOCK, which is
referenced to the 10% and 90% points).
The Ordering Information section lists temperature ranges and product
numbers. Package drawings are in the Package Information section. Refer
to the Literature List for additional documentation.
+5V
2.1KW
From Output
Under Test
200
v
100 pf
m
A
Figure 93. Test Setup
UM005001-ZMP0400