Applications Note AN36  
Issue 1 - JULY 2002  
LAYOUT CONSIDERATIONS  
The power rails to the device and to the  
windings should be kept separate where  
possible. Where the power comes onto the  
PCB it should go in one direction to the  
windings and in the other direction to the  
controller and its associated components, in  
effect to form a star connection.  
Whilst it is understandable that the circuit  
layout is likely to be severely compromised in  
the restricted environment of small 2-Phase  
brushless Fan and Blowers a number of  
points are worth mentioning.  
The capacitors for CLCK and CPWM (C1 and C2  
respectively in all the Figures) need to be  
positioned as close to the device as possible  
with the latter being the more important. The  
decoupling capacitor (C3 in all the Figures)  
also needs to be as close to the device as  
possible.  
APPLICATIONS ASSISTANCE  
Zetex Applications Engineers have a wealth  
of experience in using the ZXBM200n series  
of variable speed, 2-phase, DC brushless  
motor controllers and are always available to  
help with customer applications. Should help  
be sought please contact your nearest Zetex  
office for assistance.  
As much area as possible should be kept as  
copper for the tracks associated with the  
output stage and ground rail with the  
technique of laying out the gaps rather than  
laying out the tracks being preferred.  
Allotting as much copper to the tab of the  
winding driver transistors is beneficial when  
using surface mount packages as they rely  
upon the copper of the PCB to dissipate as  
much of the heat as possible with the PCB  
itself in effect becoming the heatsink.  
© Zetex plc 2002  
Europe  
Americas  
Asia Pacific  
Zetex plc  
Fields New Road  
Chadderton  
Oldham, OL9 8NP  
United Kingdom  
Telephone (44) 161 622 4422  
Fax: (44) 161 622 4420  
uk.sales@zetex.com  
Zetex GmbH  
Streitfeldstraße 19  
D-81673 München  
Zetex Inc  
700 Veterans Memorial Hwy  
Hauppauge, NY11788  
Zetex (Asia) Ltd  
3701-04 Metroplaza, Tower 1  
Hing Fong Road  
Kwai Fong  
Hong Kong  
Telephone: (852) 26100 611  
Fax: (852) 24250 494  
asia.sales@zetex.com  
Germany  
USA  
Telefon: (49) 89 45 49 49 0  
Fax: (49) 89 45 49 49 49  
europe.sales@zetex.com  
Telephone: (631) 360 2222  
Fax: (631) 360 8222  
usa.sales@zetex.com  
These offices are supported by agents and distributors in major countries world-wide.  
This publication is issued to provide outline information only which (unless agreed by the Company in writing) may not be used,  
applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the  
products or services concerned. The Company reserves the right to alter without notice the specification, design, price or  
conditions of supply of any product or service.  
For the latest product information, log on to www.zetex.com  
AN 36 - 14