Le75183
ELECTRICAL CHARACTERISTICS
Summary of Assumptions
Data Sheet
Unless otherwise noted, the test conditions are defined by the Le75183 device application circuit shown in
with:
V
BAT
=
−48
V, V
DD
= 5.0 V.
Supply Currents and Power Dissipation
I
DD
mA
Operational State
All OFF
Power Ringing or
Access
Idle/Talk
Condition
VDD=5V, VBAT=-48V
VDD=5V, VBAT=-48V
VDD=5V, VBAT=-48V
Min.
—
—
—
Typ
0.760
0.850
0.860
Max
1.1
2.1
1.3
Min.
—
—
—
I
BAT
µ
A
Typ
4
4
4
Max
10
10
10
LCAS Device Power mW
Min.
—
—
—
Typ
3.8
4.4
4.5
Max
6
11
7
SPECIFICATIONS
Device Specifications
Table 1. Test-In Switches, 1 and 2
Parameter
OFF-state Leakage Current:
+25°C
+85°C
–40°C
ON-resistance (SW1, SW2):
+25 °C
+85 °C
–40 °C
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity
*
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
—
—
200
1
1
1
—
V/µs
µA
I
SWITCH
(on) = ±5 mA, ±10 mA
I
SWITCH
(on) = ±5 mA, ±10 mA
I
SWITCH
(on) = ±5 mA, ±10 mA
∆
V
ON
∆
V
ON
∆
V
ON
—
—
—
49
—
37
—
77
—
Ω
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 V to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 V to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 V to +250 V
I
SWITCH
I
SWITCH
I
SWITCH
—
—
—
—
—
—
1
1
1
µA
Test Condition
Measure
Min
Typ
Max
Unit
*Applied voltage is 100 Vp-p square wave at 100 Hz. Not tested in production.
8