Le75183
Data Sheet
Table 4. Ringing Test Switch, 6
Parameter
Test Condition
Measure
Min
Typ
Max
Unit
OFF-state Leakage Current:
Vswitch (differential) = –60 to +190 V
Vswitch (differential) = +60 to –190 V
Vswitch (differential) = –60 to +200 V
Vswitch (differential) = +60 to –200 V
Vswitch (differential) = –60 to +180 V
Vswitch (differential) = +60 to –180 V
Iswitch (on) = ±70 mA, ±80 mA
Iswitch (on) = ±1 mA
ISWITCH
ISWITCH
ISWITCH
+25°C
—
—
—
—
—
—
1
1
1
+85°C
–40°C
µA
ON-resistance
ON Voltage
Steady-state Current*
Release Current
Isolation:
∆ VON
—
—
—
—
—
—
—
—
—
20
1.5
100
—
Ω
V
mA
µA
—
—
—
500
+25 °C
+85 °C
–40 °C
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
—
—
—
—
—
—
—
1
1
1
Iswitch
Iswitch
Iswitch
µA
dV/dt Sensitivity†
—
200
—
V/µs
*Choice of secondary protector and series current-limit resistor should ensure these ratings are not exceeded.
†Applied voltage is 100 Vp-p square wave at 100 Hz. Not tested in production.
Table 5. Ring Return Switch, 7
Parameter
Test Condition
Measure
Min
Typ Max Unit
OFF-state Leakage Current:
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 to +250 V
Vswitch (on) = ±20 V
ISWITCH
ISWITCH
ISWITCH
+25°C
+85°C
–40°C
—
—
—
—
—
—
1
1
1
µA
DC Current Limit
ON-resistance
ON-state Voltage*
Isolation:
Iswitch
∆ VON
VON
—
—
—
200
—
—
—
100
130
mA
Ω
Iswitch (on) = ±0 mA, ±10 mA
Iswitch = ILIMIT @ 50 Hz/60 Hz
V
+25 °C
+85 °C
–40 °C
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
—
—
—
—
—
1
1
1
Iswitch
Iswitch
Iswitch
µA
†
—
—
—
200
—
V/µs
dV/dt Sensitivity
*This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
†Applied voltage is 100 Vp-p square wave at 100 Hz. Not tested in production.
11
Zarlink Semiconductor Inc.