Le75183
Data Sheet
Table 11. Electrical Specifications, Protection Circuitry
Parameters Related to Diodes (in Diode Bridge)
Parameter
Test Condition
Measure
Min
Typ
Max
Unit
Voltage Drop at Continuous Current
(50 Hz/60 Hz)
Apply ±dc current limit of
break switches
Apply ±dynamic current
limit of break switches
Forward
Voltage
Forward
Voltage
—
—
3.5
—
V
Voltage Drop at Surge Current
—
5
Parameters Related to Protection SCR
‡
Surge Current
—
—
—
—
—
—
A
†
—
25
50
mA
Gate Trigger Current*
†
Gate Trigger Current Temperature
—
—
—
—
—
–0.5
—
%/°C
Coefficient
Hold Current
70
BAT – 4
—
—
—
—
VBAT – 2
mA
V
V
Gate Trigger Voltage
Trigger current
—
—
VBAT
Reverse Leakage Current
—
1.0
µA
—
—
0.5 A, t = 0.5 µs
2.0 A, t = 0.5 µs
VON
—
–3
–5
—
—
ON-State Voltage§
V
* Trigger Current is defined as the minimum current drawn from tip and ring to turn on the SCR. The specification in this data sheet is Gate
Trigger Current, which is defined as the maximum current that can flow into the battery before the SCR turns on.
† Typical at 25 °C
‡ Twice ± dynamic current limit of break switches.
§ In some instances, the typical ON-state voltage can range as low as –25 V.
TYPICAL PERFORMANCE CHARACTERISTICS
Figure 3. Protection Circuits
Le75183B/D
Le75183A/C
dc CURRENT-LIMIT
BREAK SWITCHES
dc CURRENT-LIMIT
BREAK SWITCHES
V
– 2
VBBAATT – 4
VBAT – 3
VBAT
VBAT
VON
<1 µA
<1 µA
3 V
3 V
50 mA
dc CURRENT LIMIT
(OF BREAK SWITCHES)
dc CURRENT LIMIT
(OF BREAK SWITCHES)
IH
17
Zarlink Semiconductor Inc.