Series current-limiting fused resistors or PTC resistors should be chosen so as not to exceed the current rating of
the external secondary protector. Refer to the manufacturer’s data sheet for specifications.
Parameters Related to Diodes (in Diode Bridge)
Parameter
Test Condition
Apply ±dc currentlimit of Forward
break switches Voltage
Apply ±dynamic current Forward
limit of break switches Voltage
Parameters Related to Protection SCR
Measure
Min.
Typ.
Max.
Unit
Voltage Drop at Continuous Current
(50 Hz/60 Hz)
—
—
3.5
V
Voltage Drop at Surge Current
—
5
—
‡
Surge Current
—
—
—
—
—
—
A
Gate Trigger Current*†
—
25
50
mA
Gate Trigger Current† Temperature
Coefficient
—
—
—
–0.5
—
%/°C
Hold Current
—
—
—
—
70
—
—
—
—
mA
V
VBAT – 4
VBAT – 2
Gate Trigger Voltage
Reverse Leakage Current
Trigger current
VBAT
—
1.0
µA
—
—
0.5 A, t = 0.5 µs
2.0 A, t = 0.5 µs
VON
—
–3
–5
—
—
ON-State Voltage§
V
* Trigger Current is defined as the minimum current drawn from tip and ring to turn on the SCR. The specification in this data
sheet is Gate Trigger Current, which is defined as the maximum current that can flow into the battery before the SCR turns on.
† Typical at 25 °C
‡ Twice ± dynamic current limit of break switches.
§ In some instances, the typical ON-state voltage can range as low as –25 V.
Table 11 - Electrical Specifications, Protection Circuitry