Data Sheet
October 2002
L8583D Line Card Access Switch
Electrical Characteristics
T
A
= –40 °C to +85 °C, unless otherwise specified.
Minimum and maximum values are testing requirements. Typical values are characteristics of the device and are
the result of engineering evaluations. Typical values are for information purposes only and are not part of the test-
ing requirements.
Table 4. Power Supply Specifications
Supply
V
DD
Min
4.5
Typ
5
Max
5.5
Unit
V
Supply
V
BAT
*
Min
–19
Typ
—
Max
–72
Unit
V
* V
BAT
is used only as a reference for internal protection circuitry. If V
BAT
rises above –10 V, the device will enter an all-off state and remain in
this state until the battery voltage drops below –15 V.
Table 5. Test In Switches, 1 and 2
Parameter
Off-state Leakage Current:
+25 °C
+85 °C
–40 °C
On-resistance:
+25 °C
+85 °C
–40 °C
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity*
Test Condition
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 V to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 V to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 V to +250 V
Iswitch (on) = ±5 mA, ±10 mA
Iswitch (on) = ±5 mA, ±10 mA
Iswitch (on) = ±5 mA, ±10 mA
Vswitch (both poles) = ±320 V,
logic inputs = Gnd
Vswitch (both poles) = ±330 V,
logic inputs = Gnd
Vswitch (both poles) = ±310 V,
logic inputs = Gnd
—
Measure
Iswitch
Iswitch
Iswitch
Min Typ Max
—
—
—
—
—
—
1
1
1
Unit
µA
µA
µA
∆
V
ON
∆
V
ON
∆
V
ON
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
—
—
49
—
37
—
—
—
200
—
77
—
1
1
1
—
Ω
Ω
Ω
µA
µA
µA
V/µs
* Applied voltage is 100 Vp-p square wave at 100 Hz.
5