L8583D Line Card Access Switch
Data Sheet
October 2002
Electrical Characteristics
(continued)
Table 12. Additional Electrical Characteristics
Parameter
Digital Input Characteristics:
Input Low Voltage
Input High Voltage
Input Leakage Current (high)
Input Leakage Current (low)
Power Requirements:
Power Dissipation
Test Condition
—
—
V
DD
= 5.5 V, V
BAT
= –75 V,
Vlogicin = 5 V
V
DD
= 5.5 V, V
BAT
= –75 V,
Vlogicin = 0 V
V
DD
= 5 V, V
BAT
= –48 V,
idle/talk state
all-off state,
ringing state or access state
V
DD
= 5 V,
idle/talk state
all-off state,
ringing state
V
BAT
= –48 V,
idle/talk state
all-off state,
ringing state or access state
—
—
V
DD
= 5.5 V, V
BAT
= –58 V,
Vlogicin = 5 V
V
DD
= 5.5 V, V
BAT
= –58 V,
Vlogicin = 0 V
V
DD
= 5.5 V, V
BAT
= –58 V,
Vlogicin = 5 V
V
DD
= 5.5 V, V
BAT
= –58 V,
Vlogicin = 0 V
—
—
Measure
—
—
llogicin
llogicin
Min
—
3.5
—
—
Typ
—
—
—
—
Max Unit
1.5
—
500
500
V
V
µA
µA
I
DD
, I
BAT
I
DD
, I
BAT
I
DD
, I
BAT
I
DD
I
DD
I
DD
I
BAT
I
BAT
I
BAT
—
—
llogicin
llogicin
llogicin
llogicin
—
—
—
—
—
—
—
—
—
—
3.5
—
—
—
—
4.5
3.8
4.4
0.860
0.760
0.850
4
4
4
—
—
0.5
100
100
0.5
7
6
11
1.3
1.1
2.1
10
10
10
1.5
—
—
—
—
—
mW
mW
mW
mA
mA
mA
µA
µA
µA
V
V
µA
µA
µA
µA
V
DD
Current
V
BAT
Current
Digital Input Characteristics:
Input Low Voltage
Input High Voltage
Input Leakage Current (high)
IN
TESTOUT
, IN
RING
Input Leakage Current (low)
IN
TESTOUT
, IN
RING
Input Leakage Current (high)
IN
TESTIN
, LATCH
Input Leakage Current (low)
IN
TESTIN
, LATCH
Temperature Shutdown Requirements*:
Shutdown Activation Temperature
Shutdown Circuit Hysteresis
—
—
110
10
125
—
150
25
°C
°C
* Temperature shutdown flag (T
SD
) will be high during normal operation and low during temperature shutdown state.
Zero Cross Current Turn Off
The ring access switch (SW8) is designed to turn off on the next zero current crossing after application of the
appropriate logic input control. This switch requires a current zero cross to turn off. Switch 8, once on, will remain in
the on state (regardless of logic input) until a current zero cross. Therefore, to ensure proper operation of switch 8,
this switch should be connected, via proper impedance, to the ringing generator or some other ac source. Do not
attempt to switch pure dc with switch 8. The ringing test access switch, SW6, also has similar characteristics to
switch 8 and should also only be used to switch signals with zero current crossings. For a detailed explanation of
the operation of switches 6 and 8, please refer to the
An Introduction to L758X Series of Line Card Access
Switches
Application Note.
10