AC-DC Power Supplies
CCL400 Series
Mechanical Details
CCL400 Covered (-C)
SIGNALS CONNECTOR CON4
10 WAY JST B10B-PHDSS
PIN1
PIN2
1.92 (48.9)
PIN9
PIN10
7.47 (189.9)
DETAIL A
SCALE 1 : 1
7.39 (187.8)
A
OUTPUTVOLTAGE
CONTROL
+VE
-VE
1
2
3
OUTPUTTERMINALS
M4 SCREWS IN 2 POSITIONS
TORQUETO 8 lbs-in (90 cNm) MAX.
Input Connector CON1
Optional Input Connector CON1 (add suffix ‘-S’)
0.79 (20.1)
3.24 (82.4)
6.45 (163.9)
1.25 (31.9)
0.52 (13.3)
3 Way DINKLE DT-2C-B14W-03
M3 SCREWS IN 3 POSTIONS
TORQUETO 7lbs-in (80 cNm) MAX.
4x M3 Max depth 3mm [0.12]
4.22 (107.3)
4.04 (102.5)
CON1 Input Connector
CON4 Signals Connector
Output Connector
(Dinkle 166-0P33)
Function
Line
(JST B10B-PHDSS)
Function
Pin
1
Pin
1
Function
+V1
Pin
1
+ Standby
2
Neutral
2
+V1 RTN
2
+ Standby
3
Earth
3
- Standby
4
- Standby
5
6
7
8
Power Fail (Emitter)
Power Fail (Collector)
Inhibit (Cathode)
Inhibit (Anode)
- Sense
Notes
1. Dimensions shown in inches (mm).
2. CON4 Mating Plug: JST-PHDR-10VS
Contact: 26-22-AWG (JST-SPHD-001T-P0.5
3. For optional screw terminal input connector, add suffix ‘-S’
to the model number. i.e. CCL400PS12-S (contact sales for
availability).
9
10
+ Sense
www.xppower.com
7