CCL400 Series
Signals & Controls
Characteristic
Power Fail (AC-OK)
Inhibit
Standby Supply
Remote Sense
AC-DC Power Supplies
Notes & Conditions
Uncomitted opto isolated transistor, normally off when AC is good (see fig.5)
Provides 5 - 15ms warning of loss of output from AC failure off when AC is healthy.
Uncommited isolated optocoupler diode, powered diode inhibits the supply (see fig.6 & 7)
5V/0.5A Isolated supply present when AC applied.
Compensates for 0.25V per lead, 0.5V total drop.
Power Fail
Figure 5
Inhibit (High)
Figure 6
5V
Inhibit (Low)
Figure 7
V
5V
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
8V Max 3 mA
Pin 6 CON 4
Power Fail
Collector
Transistor On: Input & Output Not OK
Transistor Off: Input & Output OK
5 mA, 8 V, Max
Inhibit Hi
Pin 8 CON 4
1K
8 V Max
Inhibit Hi
Pin 8
CON 4
5 mA, max
Inhibit Lo
Pin 7 CON 4
1K
Power Fail
Emitter
Pin 5 CON 4
Inhibit Lo
Pin 7 CON 4
Signal Connector
VI RTN
Pin 3 CON 4
Signal Connector
VI RTN
Pin 3 CON 4
Signal Connector
Environmental
Characteristic
Operating Temperature
Storage Temperature
Cooling
Humidity
Operating Altitude
Shock
Vibration
Minimum
-40
-40
Typical
5V
Maximum
+70
+85
Units
°C
°C
Notes & Conditions
See derating curve, fig.8. and Thermal
Considerations on page 8.
Convection or conduction-cooled with 0.5 °C/W or
better heatsink
Non-condensing
95
%RH
5000
m
±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (±0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47
Single axis 10 - 500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
V
Temperature Derating Curve
Figure 8 - No Cover Fitted
Output Power (W)
400
300
200
100
0
-40
Some specification parameters
may not be met
S
Conduction-cooled
90 - 264 VAC
Convection-cooled 100 - 264 VAC
&
Conduction-cooled 90 - 264 VAC
176 W
-30
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
Figure 9 - Cover Fitted
Output Power (W)
400
322
300
200
100
0
-40
Conduction-cooled 90 - 264 VAC
Some specification parameters
may not be met
Convection-cooled 90 - 264 VAC
201 W
161 W
-30
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
www.xppower.com
4