CCL400 Series
Input
Characteristic
Input Voltage - Operating
Input Voltage - Fault Condition
Input Frequency
Power Factor
Input Current - Full Load
No Load Input Power
Inrush Current
Earth Leakage Current
Input Protection
35
90/180
47
50/60
>0.95
3.8/1.9
1
60
250
Minimum
85
Typical
115/230
Maximum
264
300
63
AC-DC Power Supplies
Units
VAC
VAC
Hz
Notes & Conditions
Derate output power < 100 VAC for convection cooling or
<90 VAC for conduction cooling. See fig. 1
5 seconds max
Agency approval, 47-63 Hz
EN61000-3-2 class A compliant
EN61000-3-2 class C for loads ≥10%
A
W
A
µA
115/230 VAC
All models, when inhibit activated
230 VAC
Typ. 115/230 VAC 50 Hz, Max 264 VAC 60 Hz
F10.0 A 250 V internal fuse in both AC lines
Input Voltage Derating
Figure 1
Conduction Cooled with and without cover
400
350
Output Power (W)
300
200
100
0
Convection Cooled without cover
Convection Cooled with cover
85 90
100
Input Voltage (V)
264
Output
Characteristic
Output Voltage
Initial Set Accuracy
Output Voltage Adjustment
Minimum Load
Start Up Delay
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature Coefficient
Overtemperature Protection
0.05
%/˚C
Shutdown and auto recovery
115
110
0
1.5
30
±0.2
0.5
0.5
<4
1
140
150
2.0
Minimum
12
Typical
Maximum
48
±0.5
±3
Units
VDC
%
%
A
s
ms
%
%
%
%
% pk-pk
%
%
Recovery within 1% in less than 500 µs
for a 50-75%-50% load change
20 MHz bandwidth
Vnom DC. Output 1, recycle input to reset
Trip & Restart characteristic V1
Shutdown and auto recovery
After 20 min warm up
115/230 VAC full load from input AC turn on
Notes & Conditions
See Models and Ratings table
50% load, 115/230 VAC
www.xppower.com