R
Virtex-II Platform FPGAs: DC and Switching Characteristics
Table 4: Quiescent Supply Current
Symbol
Description
Device
Min
Typical
Max
Units
XC2V40
XC2V80
3
5
8
125
125
150
200
250
350
400
500
650
800
1100
XC2V250
XC2V500
XC2V1000
XC2V1500
XC2V2000
XC2V3000
XC2V4000
XC2V6000
XC2V8000
10
12
15
20
27
35
45
60
mA
I
Quiescent V
Quiescent V
Quiescent V
supply current
CCINT
CCINTQ
XC2V40
XC2V80
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
XC2V250
XC2V500
XC2V1000
XC2V1500
XC2V2000
XC2V3000
XC2V4000
XC2V6000
XC2V8000
(1,2)
mA
I
supply current
CCOQ
CCO
XC2V40
XC2V80
5
5
5
5
5
7.5
7.5
10
10
12.5
12.5
25
25
25
25
25
50
50
75
75
XC2V250
XC2V500
XC2V1000
XC2V1500
XC2V2000
XC2V3000
XC2V4000
XC2V6000
XC2V8000
(1,2)
mA
I
supply current
CCAUXQ
CCAUX
100
100
Notes:
1. With no output current loads, no active input pull-up resistors, all I/O pins are 3-state and floating.
2. If DCI or differential signaling is used, more accurate values can be obtained by using the Power Estimator or XPOWER™.
3. Data are retained even if VCCO drops to 0 V.
4. Values specified for quiescent supply current parameters are Commercial Grade. For Industrial Grade values, multiply Commercial
Grade values by 1.25.
If any V
bank powers up before V
, then each bank
CCAUX
Power-On Power Supply Requirements
CCO
draws up to 300 mA, worst case, until the V
powers
CCAUX
Xilinx FPGAs require a certain amount of supply current
during power-on to insure proper device operation. The
actual current consumed depends on the power-on ramp
rate of the power supply.
(2)
up. This does not harm the device. If the current is limited
to the minimum value above, or larger, the device powers on
properly after all three supplies have passed through their
power-on reset threshold voltages.
The V
, V
, and V
power supplies shall each
CCO
CCINT CCAUX
Once initialized and configured, use the power calculator to
estimate current drain on these supplies.
ramp on, monotonically, no faster than 200 μs and no slower
than 50 ms. Ramp on is defined as: 0 V to minimum sup-
DC
Notes:
ply voltages.
1. If the VCCINT ramp rate is longer than 10 ms, then VCCINT must
be applied before VCCO and VCCAUX. The device will not be
damaged if this requirement is violated, but configuration will
probably fail.
2. The 300 mA is transient current (peak); it eventually
disappears even if VCCAUX does not power up.
Table 5 shows the minimum current required by Virtex-II
devices for proper power on and configuration.
(1)
Power supplies can be turned on in any sequence.
DS031-3 (v3.5) November 5, 2007
Product Specification
www.xilinx.com
Module 3 of 4
3