X24128
ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature under Bias
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
X24128.......................................–65°C to +135°C
Storage Temperature........................–65°C to +150°C
Voltage on any Pin with
Respect to V ....................................–1V to +7V
SS
D.C. Output Current ..............................................5mA
Lead Temperature
(Soldering, 10 seconds) ..............................300°C
RECOMMENDED OPERATING CONDITIONS
Supply Voltage
X24128
Limits
Temperature
Commercial
Industrial
Min.
0°C
Max.
+70°C
+85°C
4.5V to 5.5V
2.5V to 5.5V
1.8V to 3.6V
X24128–2.5
X24128–1.8
–40°C
7027 FRM T04
7027 FRM T05
D.C. OPERATING CHARACTERISTICS
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
ICC1
VCC Supply Current (Read)
1
3
mA SCL = VCC X 0.1/VCC X 0.9 Levels
@ 400KHz, SDA = Open, All Other
ICC2
VCC Supply Current (Write)
VCC Standby Current
mA
Inputs = V or VCC – 0.3V
SS
(1)
5
µA
µA
SCL = SDA = VCC, All Other
ISB1
Inputs = V or VCC – 0.3V,
SS
VCC = 5V ± 10%
(1)
VCC Standby Current
1
SCL = SDA = VCC, All Other
ISB2
Inputs = V or VCC – 0.3V,
SS
VCC = 2.5V
ILI
Input Leakage Current
Output Leakage Current
Input LOW Voltage
10
10
µA
µA
V
V
IN = V to VCC
SS
ILO
VOUT = V to VCC
SS
(2)
–0.5
VCC x 0.3
VCC + 0.5
0.4
VlL
(2)
Input HIGH Voltage
Output LOW Voltage
VCC x 0.7
V
VIH
VOL
V
V
IOL = 3mA
(3)
Hysteresis of Schmitt
Trigger Inputs
VCC x 0.05
Vhys
7027 FRM T06
CAPACITANCE T = +25°C, f = 1MHz, V = 5V
A
CC
Symbol
Parameter
Max.
Units
Test Conditions
(3)
Input/Output Capacitance (SDA)
8
pF
VI/O = 0V
CI/O
(3)
Input Capacitance (S0, S1, S2, SCL, WP)
6
pF
VIN = 0V
CIN
7027 FRM T07
Notes: (1) Must perform a stop command prior to measurement.
(2) V min. and V max. are for reference only and are not 100% tested.
IL
IH
(3) This parameter is periodically sampled and not 100% tested.
11