 浏览型号X1202V8-4.5A的Datasheet PDF文件第12页浏览型号X1202V8-4.5A的Datasheet PDF文件第13页浏览型号X1202V8-4.5A的Datasheet PDF文件第14页浏览型号X1202V8-4.5A的Datasheet PDF文件第15页浏览型号X1202V8-4.5A的Datasheet PDF文件第17页浏览型号X1202V8-4.5A的Datasheet PDF文件第18页浏览型号X1202V8-4.5A的Datasheet PDF文件第19页浏览型号X1202V8-4.5A的Datasheet PDF文件第20页  
X1202  
Notes: (1) The device enters the active state after any start, and remains active: for 9 clock cycles if the device select bits in the slave address  
byte are incorrect or until 200ns after a stop ending a read or write operation.  
(2) The device enters the program state 200ns after a stop ending a write operation and continues for t  
.
WC  
(3) The device goes into the timekeeping state 200ns after any stop, except those that initiate a nonvolatile write cycle; t  
after a stop  
WC  
that initiates a nonvolatile write cycle; or 9 clock cycles after any start that is not followed by the correct device select bits in the slave  
address byte.  
(4) For reference only and not tested.  
(5) V = V x 0.1, V = V x 0.9, f  
= 400kHz, SDA = open  
IL  
CC  
IH  
CC  
SCL  
SCL  
(6) V = V x 0.1, V = V x 0.9, f  
= 400kHz, f  
= 400kHz, V = 1.22 x V Min  
IL  
CC  
IH  
CC  
SDA CC CC  
(7) V = 0V  
CC  
(8) V  
(9) V  
(10)V  
(11)V  
= 0V  
BACK  
= V  
= V , Others = GND or V  
CC CC  
SDA  
SDA  
SDA  
SCL  
= V  
= V  
, Others = GND or V  
SCL  
BACK BACK  
= GND to V  
V
= GND or V  
CC, CLK CC  
(12)I = 3.0mA at 5V, 1.5mA at 2.7V  
OL  
(13)I  
= -1.0mA at 5V, -0.4mA at 2.7V  
OH  
(14)Threshold voltages based on the higher of V or V  
.
BACK  
CC  
(15)Driven by external 32.768kHz square wave oscillator on X1, X2 open.  
(16)Using recommended crystal and oscillator network applied to X1 and X2 (25°C).  
(17)Periodically sampled and not 100% tested  
CAPACITANCE T = 25°C, F = 1.0 MHZ, V  
= 5V  
A
CC  
Symbol  
Parameter  
Max.  
Unit  
pF  
Test Condition  
= 0V  
(1)  
C
Output capacitance (SDA, RESET)  
Input capacitance (SCL)  
8
6
V
OUT  
OUT  
(1)  
C
pF  
V
= 0V  
IN  
IN  
Note: (1) This parameter is periodically sampled and not 100% tested.  
AC CHARACTERISTICS  
AC Test Conditions  
EQUIVALENT AC OUTPUT LOAD CIRCUIT FOR  
= 5V (standard output load for testing the device  
V
CC  
with V  
= 5.0V)  
CC  
Input pulse levels  
V
x 0.1 to V x 0.9  
CC  
CC  
5.0V  
Input rise and fall times  
Input and output timing levels  
Output load  
10ns  
V
x 0.5  
CC  
For V = 0.4V  
OL  
1533Ω  
Standard output load  
and I = 3 mA  
OL  
SDA  
100pF  
Characteristics subject to change without notice. 16 of 23  