TABLE II. Electrical test requirements. 1/ 2/ 3/ 4/ 5/
MIL-STD-883 test requirements
Subgroups
(in accordance with
MIL-STD-883, method 5005,
table I)
Interim electrical parameters
(method 5004)
1, 7, 9, or
2, 8A, 10
Final electrical test parameters
(method 5004)
1*, 2, 3, 7*, 8A, 8B, 9, 10, 11
Group A test requirements
(method 5005)
1, 2, 3, 4**, 7, 8A, 8B, 9, 10,
11
Groups C and D end-point
electrical parameters
(method 5005)
1, 2, 3, 7, 8A, 8B, 9, 10, 11
1/ (*) Indicates PDA applies to subgroups 1 and 7.
2/ Any or all subgroups may be combined when using multifunction testers.
3/ Subgroups 7, 8A, and 8B shall consist of writing and reading the data
pattern specified in accordance with the limits of table I,
subgroups 9, 10, and 11.
4/ For all electrical tests, the device shall be programmed to the data
pattern specified.
5/ (**) Indicates that subgroup 4 will only be performed during initial testing
and after design or process changes (see 4.3.1c).
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.1.1 Replacability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.3 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system
application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be used
for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC 5962)
should contact DSCC-VA, telephone (614) 692-0544.
6.4 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone
(614) 692-0547.
6.5 Approved sources of supply . Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-HDBK-
103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted by DSCC-
VA.
SIZE
STANDARD
5962-88634
MICROCIRCUIT DRAWING
A
REVISION LEVEL
F
SHEET
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
19
DSCC FORM 2234
APR 97