WPMIx9200501S / 1779205x4
MagI3C Power Module
FISM – Fixed Isolated SIP Module
ELECTRICAL SPECIFICATIONS
MIN and MAX limits are valid for the recommended ambient temperature range of -40°C to 85°C. Typical values represents
statistically the utmost probability at following conditions: TA = 25°C, VIN = 5V VOUT = 5V (177920514), VIN = 12V, VOUT = 5V
(177920524), VIN = 24V, VOUT = 5V (177920534), IOUT = 0.2A unless otherwise noted.
SYMBOL
PARAMETER
TEST CONDITIONS
Output Current
5s
MIN (1)
TYP (3)
MAX (1)
UNIT
IMOC
IOCP
Maximum overload current
Over current protection
-
-
-
-
300(6)
No (7)
mA
mA
Accuracy
per 1.0% change in input
voltage(8)
Line regulation
Load regulation
-
-
±1.2
-
-
%
%
10% to 100% load current,
5Vout – see tolerance
envelope
-5
+15
VOUT
Output voltage accuracy
Output voltage ripple
Vin nominal
-
-
-
±5
-
%
20MHz BW, without external
MLCC capacitor
60
mVpp
Switching frequency
VIN = 12V
fSW
Switching frequency
50
-
105
kHz
Input current
177920514
-
-
-
30
15
10
-
-
-
mA
mA
mA
No load input current
(Operating, switching)
IIN
177920524
177920534
Efficiency
VIN = 5V, VOUT = 5V
VIN = 12V, VOUT = 5V
VIN = 24V, VOUT = 5V
-
-
-
75
80
81
-
-
-
%
%
%
η
Efficiency
RELIABILITY
SYMBOL
MIN (1)
TYP (3)
13200 x103h
5200 x103h
MAX (1)
UNIT
CONDITIONS
+25°C: Ground Benign
+85°C: Ground Benign
PARAMETER
h
h
MTBF(9)
Mean Time Between Failures
APPROVALS
Recognized for use as Information Technology Equipment, U.S.A. (UL
60950-1) - pending and Canada (C22.2 No. 60950-1) - pending;
applicable for altitudes up to 2000m
UL 60950
we-online.com
©July 2016
Würth Elektronik eiSos GmbH & Co. KG – Data Sheet Rev. 1.0