WM8912  
Production Data  
DESCRIPTION  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
8
WSEQ_EINT_DB  
0
Write Sequencer interrupt  
debounce enable  
0 = disabled  
1 = enabled  
5
2
GPIO1_EINT_DB  
0
0
GPIO1 input debounce  
0 = disabled  
1 = enabled  
FLL_LOCK_EINT_D  
B
FLL Lock debounce  
0 = disabled  
1 = enabled  
Table 54 Interrupt Control  
CONTROL INTERFACE  
The WM8912 is controlled by writing to registers through a 2-wire serial control interface. Readback  
is available for all registers, including Chip ID, power management status and GPIO status.  
Note that, if it cannot be assured that MCLK is present when accessing the register map, then it is  
required to set CLK_SYS_ENA = 0 to ensure correct operation. See “Clocking and Sample Rates”  
for details of CLK_SYS_ENA.  
The WM8912 is a slave device on the control interface; SCLK is a clock input, while SDA is a bi-  
directional data pin. To allow arbitration of multiple slaves (and/or multiple masters) on the same  
interface, the WM8912 transmits logic 1 by tri-stating the SDA pin, rather than pulling it high. An  
external pull-up resistor is required to pull the SDA line high so that the logic 1 can be recognised by  
the master.  
In order to allow many devices to share a single 2-wire control bus, every device on the bus has a  
unique 8-bit device ID (this is not the same as the 8-bit address of each register in the WM8912).  
The WM8912 device ID is 0011 0100 (34h). The LSB of the device ID is the Read/Write bit; this bit is  
set to logic 1 for “Read” and logic 0 for “Write”.  
The WM8912 operates as a slave device only. The controller indicates the start of data transfer with  
a high to low transition on SDA while SCLK remains high. This indicates that a device ID, register  
address and data will follow. The WM8912 responds to the start condition and shifts in the next eight  
bits on SDA (8-bit device ID including Read/Write bit, MSB first). If the device ID received matches  
the device ID of the WM8912, then the WM8912 responds by pulling SDA low on the next clock  
pulse (ACK). If the device ID is not recognised or the R/W bit is ‘1’ when operating in write only  
mode, the WM8912 returns to the idle condition and waits for a new start condition and valid  
address.  
If the device ID matches the device ID of the WM8912, the data transfer continues as described  
below. The controller indicates the end of data transfer with a low to high transition on SDA while  
SCLK remains high. After receiving a complete address and data sequence the WM8912 returns to  
the idle state and waits for another start condition. If a start or stop condition is detected out of  
sequence at any point during data transfer (i.e. SDA changes while SCLK is high), the device returns  
to the idle condition.  
The WM8912 supports the following read and write operations:  
Single write  
Single read  
Multiple write using auto-increment  
Multiple read using auto-increment  
PD, Rev 4.0, September 2010  
80  