Production Data
WM8737L
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously
operating at or beyond these limits. Device functional operating limits and guaranteed performance specifications are given
under Electrical Characteristics at the test conditions specified.
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically susceptible
to damage from excessive static voltages. Proper ESD precautions must be taken during handling and storage
of this device.
Wolfson tests its package types according to IPC/JEDEC J-STD-020B for Moisture Sensitivity to determine acceptable storage
conditions prior to surface mount assembly. These levels are:
MSL1 = unlimited floor life at <30C / 85% Relative Humidity. Not normally stored in moisture barrier bag.
MSL2 = out of bag storage for 1 year at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.
MSL3 = out of bag storage for 168 hours at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.
CONDITION
MIN
MAX
+3.63V
Supply voltages
-0.3V
Voltage range digital inputs
Voltage range analogue inputs
DGND -0.3V
AGND -0.3V
AGND -0.3V
DBVDD +0.3V
AVDD +0.3V
MVDD +0.3V
40MHz
Voltage range LACIN, RACIN, LACOUT, RACOUT, MICBIAS
Master Clock Frequency
Operating temperature range, TA
Storage temperature after soldering
Notes:
-25C
-65C
+85C
+150C
1. Analogue and digital grounds must always be within 0.3V of each other.
2. All digital and analogue supplies are completely independent from each other.
RECOMMENDED OPERATING CONDITIONS
PARAMETER
SYMBOL
DCVDD
TEST CONDITIONS
MIN
1.42
1.8
TYP
MAX
3.6
UNIT
Digital supply range (Core)
Digital supply range (I/O Buffers)
Analogue supplies range
Ground
V
V
V
V
DBVDD
3.6
AVDD, MVDD
DGND, AGND
1.8
3.6
0
Notes:
1.
DBVDD must be greater than or equal to DCVDD.
PD, Rev 4.4, January 2012