欢迎访问ic37.com |
会员登录 免费注册
发布采购

WM8523GEFL/V 参数 Datasheet PDF下载

WM8523GEFL/V图片预览
型号: WM8523GEFL/V
PDF下载: 下载PDF文件 查看货源
内容描述: [24-bit 192kHz Stereo DAC with 2Vrms Ground Referenced Line Output]
分类和应用: 转换器
文件页数/大小: 51 页 / 618 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8523GEFL/V的Datasheet PDF文件第4页浏览型号WM8523GEFL/V的Datasheet PDF文件第5页浏览型号WM8523GEFL/V的Datasheet PDF文件第6页浏览型号WM8523GEFL/V的Datasheet PDF文件第7页浏览型号WM8523GEFL/V的Datasheet PDF文件第9页浏览型号WM8523GEFL/V的Datasheet PDF文件第10页浏览型号WM8523GEFL/V的Datasheet PDF文件第11页浏览型号WM8523GEFL/V的Datasheet PDF文件第12页  
WM8523  
Production Data  
ABSOLUTE MAXIMUM RATINGS  
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously operating at or  
beyond these limits. Device functional operating limits and guaranteed performance specifications are given under Electrical  
Characteristics at the test conditions specified.  
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically  
susceptible to damage from excessive static voltages. Proper ESD precautions must be taken during  
handling and storage of this device.  
Wolfson tests its package types according to IPC/JEDEC J-STD-020B for Moisture Sensitivity to determine acceptable storage  
conditions prior to surface mount assembly. These levels are:  
MSL1 = unlimited floor life at <30°C / 85% Relative Humidity. Not normally stored in moisture barrier bag.  
MSL2 = out of bag storage for 1 year at <30°C / 60% Relative Humidity. Supplied in moisture barrier bag.  
MSL3 = out of bag storage for 168 hours at <30°C / 60% Relative Humidity. Supplied in moisture barrier bag.  
The Moisture Sensitivity Level for each package type is specified in Ordering Information.  
CONDITION  
MIN  
-0.3V  
MAX  
+4.5V  
AVDD, LINEVDD  
Voltage range digital inputs  
Voltage range analogue inputs  
Temperature range, TA  
LINEGND -0.3V  
AGND -0.3V  
-40°C  
LINEVDD +0.3V  
AVDD +0.3V  
+125°C  
Storage temperature after soldering  
-65°C  
+150°C  
Notes  
1. Analogue grounds must always be within 0.3V of each other.  
2. LINEVDD and AVDD must always be within 0.3V of each other.  
RECOMMENDED OPERATING CONDITIONS  
PARAMETER  
Analogue supply range  
Ground  
SYMBOL  
TEST CONDITIONS  
MIN  
TYP  
MAX  
UNIT  
AVDD, LINEVDD  
AGND, LINEGND  
2.97  
3.3  
0
3.63  
V
V
PD, Rev 4.1, August 2011  
8
w