Production Data  
WM8352  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
0 0000 = 0.9V  
Register CAh LDO1 Low Power  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
LDO2 Regulator mode  
REFER TO  
R203 (CBh)  
LDO2  
Control  
14  
LDO2_SWI  
0
0 = LDO voltage regulator  
1 = Current-limited switch (no voltage regulation,  
LDO2_VSEL has no effect)  
Reset by state machine. Default held in metal mask.  
10  
LDO2_OPFLT  
0
Enable discharge of LDO2 outputs when LDO2 is  
disabled  
0 = Enabled - Output to be discharged  
1 = Disabled - Output is left floating  
Note - if LDO Regulators 1, 2, 3 and 4 are all  
disabled, then the outputs will all be discharged,  
regardless of the LDOn_OPFLT bit.  
4:0  
LDO2_VSEL[4:0] 1_1011  
LDO2 Regulator output voltage (when LDO2_SWI=0)  
1_1010  
0_0110  
1_0111  
1 1111 = 3.3V  
… (100mV steps)  
1 0000 = 1.8V  
0 1111 = 1.65V  
… (50mV steps)  
0 0000 = 0.9V  
Reset by state machine. Default held in metal mask.  
Register CBh LDO2 Control  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R204 (CCh) 15:14 LDO2_ERRACT[1:0]  
00  
Action to take on LDO2 fault (as well as  
generating an interrupt):  
LDO2  
Timeouts  
00 = ignore  
01 = shut down regulator  
10 = shut down system  
11 = reserved (shut down system)  
Reset by state machine. Default held in metal  
mask.  
13:10 LDO2_ENSLOT[3:0]  
0000  
0000  
0001  
0100  
Time slot for LDO2 start-up  
0000 = Disabled (do not start up)  
0001 = Start-up in time slot 1  
… (total 14 slots available)  
1110 = Start-up in time slot 14  
1111 = Start up on entering ACTIVE  
Reset by state machine. Default held in metal  
mask.  
9:6  
LDO2_SDSLOT[3:0]  
0000  
Time slot for LDO2 shutdown.  
0000 = Shut down on entering OFF  
0001 = Shutdown in time slot 1  
…. (total 14 slots available)  
1110 = Shutdown in time slot 14  
1111 = Shut down on entering OFF  
Register CCh LDO2 Timeouts  