Production Data
WM8326
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
REFER TO
R16489
(4069h)
LDO1 ON
Control
LDO1_ON_SL
OT [2:0]
LDO1 ON Slot select
000 = Do not enable
15:13
000
001 = Enable in Timeslot 1
010 = Enable in Timeslot 2
011 = Enable in Timeslot 3
100 = Enable in Timeslot 4
101 = Enable in Timeslot 5
110 = Controlled by Hardware Enable 1
111 = Controlled by Hardware Enable 2
LDO1 ON Operating Mode
0 = Normal mode
LDO1_ON_MO
DE
8
0
1 = Low Power mode
LDO1_ON_VS
EL [4:0]
LDO1 ON Voltage select
4:0
0_0000
0.9V to 1.6V in 50mV steps
1.7V to 3.3V in 100mV steps
00h = 0.90V
01h = 0.95V
…
0Eh = 1.60V
0Fh = 1.70V
…
1Eh = 3.20V
1Fh = 3.30V
Register 4069h LDO1 ON Control
REGISTER
ADDRESS
BIT
LABEL
DEFAULT
DESCRIPTION
REFER TO
R16490
(406Ah)
LDO1
LDO1_SLP_SL
OT [2:0]
LDO1 SLEEP Slot select
15:13
000
000 = SLEEP voltage / operating mode transition in
Timeslot 5
SLEEP
Control
001 = Disable in Timeslot 5
010 = Disable in Timeslot 4
011 = Disable in Timeslot 3
100 = Disable in Timeslot 2
101 = Disable in Timeslot 1
110 = SLEEP voltage / operating mode transition in
Timeslot 3
111 = SLEEP voltage / operating mode transition in
Timeslot 1
If LDO1 is assigned to a Hardware Enable Input, then
codes 001-101 select in which timeslot the regulator
enters its SLEEP condition.
LDO1_SLP_M
ODE
LDO1 SLEEP Operating Mode
0 = Normal mode
8
1
1 = Low Power mode
LDO1_SLP_VS
EL [4:0]
LDO1 SLEEP Voltage select
0.9V to 1.6V in 50mV steps
1.7V to 3.3V in 100mV steps
4:0
0_0000
00h = 0.90V
01h = 0.95V
…
PD, June 2012, Rev 4.0
203
w