欢迎访问ic37.com |
会员登录 免费注册
发布采购

WM8326GEFL/RV 参数 Datasheet PDF下载

WM8326GEFL/RV图片预览
型号: WM8326GEFL/RV
PDF下载: 下载PDF文件 查看货源
内容描述: 处理器电源管理子系统 [Processor Power Management Subsystem]
分类和应用:
文件页数/大小: 255 页 / 1340 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8326GEFL/RV的Datasheet PDF文件第197页浏览型号WM8326GEFL/RV的Datasheet PDF文件第198页浏览型号WM8326GEFL/RV的Datasheet PDF文件第199页浏览型号WM8326GEFL/RV的Datasheet PDF文件第200页浏览型号WM8326GEFL/RV的Datasheet PDF文件第202页浏览型号WM8326GEFL/RV的Datasheet PDF文件第203页浏览型号WM8326GEFL/RV的Datasheet PDF文件第204页浏览型号WM8326GEFL/RV的Datasheet PDF文件第205页  
Production Data  
WM8326  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
DC-DC4 ON Slot select  
REFER TO  
R16486  
(4066h) DC4  
ON Config  
DC4_ON_SLO  
T [2:0]  
15:13  
000  
000 = Do not enable  
001 = Enable in Timeslot 1  
010 = Enable in Timeslot 2  
011 = Enable in Timeslot 3  
100 = Enable in Timeslot 4  
101 = Enable in Timeslot 5  
110 = Controlled by Hardware Enable 1  
111 = Controlled by Hardware Enable 2  
DC-DC4 ON Operating Mode  
00 = Forced Continuous Conduction Mode  
DC4_ON_MOD  
E [1:0]  
9:8  
6:2  
01  
01 = Auto Mode (Continuous / Discontinuous  
Conduction with Pulse-Skipping)  
10 = LDO Mode  
11 = Hysteretic Mode  
DC-DC4 ON Voltage select  
DC4_ON_VSE  
L [6:2]  
0_0000  
DC4_ON_VSEL [6:0] selects the DC-DC4 output  
voltage from 0.85V to 3.4V in 25mV steps.  
DC4_ON_VSEL [6:2] also exist in ICE/OTP memory,  
controlling the voltage in 100mV steps.  
DC4_ON_VSEL [6:0] is coded as follows:  
00h = 0.85V  
01h = 0.875V  
65h = 3.375V  
66h to 7Fh = 3.4V  
DC-DC4 ON Voltage select  
DC4_ON_VSE  
L [1:0]  
1:0  
00  
DC4_ON_VSEL [6:0] selects the DC-DC4 output  
voltage from 0.85V to 3.4V in 25mV steps.  
See DC4_ON_VSEL [6:2] for definition.  
Register 4066h DC4 ON Config  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16487  
(4067h) DC4  
SLEEP  
DC4_SLP_SLO  
T [2:0]  
DC-DC4 SLEEP Slot select  
15:13  
000  
000 = SLEEP voltage / operating mode transition in  
Timeslot 5  
Control  
001 = Disable in Timeslot 5  
010 = Disable in Timeslot 4  
011 = Disable in Timeslot 3  
100 = Disable in Timeslot 2  
101 = Disable in Timeslot 1  
110 = SLEEP voltage / operating mode transition in  
Timeslot 3  
111 = SLEEP voltage / operating mode transition in  
Timeslot 1  
If DC-DC4 is assigned to a Hardware Enable Input,  
then codes 001-101 select in which timeslot the  
converter enters its SLEEP condition.  
PD, June 2012, Rev 4.0  
201  
w
 复制成功!