WM8321  
Production Data  
DESCRIPTION  
ADDRESS  
BIT  
LABEL  
DEFAULT  
LDOn_UV_S  
TS  
LDOn Undervoltage Status  
0 = Normal  
9:0  
0
1 = Undervoltage  
Notes:  
1. n is a number between 1 and 10 that identifies the individual LDO Regulator (LDO1 - 10).  
2. m is a number between 1 and 4 that identifies the individual DC-DC Converter (DC-DC1 - 4).  
Table 38 DC Converter and LDO Regulator Status  
15.12 POWER MANAGEMENT INTERRUPTS  
Undervoltage monitoring is provided on all DC-DC Converters and LDO Regulators, as described in  
Section 15.10. The associated interrupt flags indicate an undervoltage condition in each individual  
DC-DC Converter or LDO Regulator. Each of these secondary interrupts triggers a primary  
Undervoltage Interrupt, UV_INT (see Section 23). This can be masked by setting the mask bit(s) as  
described in Table 39.  
Current monitoring is provided on DC-DC1 and DC-DC2, as described in Section 15.10. The interrupt  
flags HC_DC1_EINT and HC_DC2_EINT indicate a high current condition in DC-DC1 and DC-DC2  
respectively. Each of these secondary interrupts triggers a primary High Current Interrupt, HC_INT  
(see Section 23). This can be masked by setting the mask bit(s) as described in Table 39.  
The high current thresholds are programmable; these are set by DC1_HC_THR and DC2_HC_THR  
for DC-DC1 and DC-DC2 respectively. See Section 15.11.2 for details of these register fields. Note  
that these functions are for current monitoring; they do not equate to the DC-DC Converter maximum  
current limit.  
ADDRESS  
R16403  
(4013h)  
BIT  
LABEL  
DESCRIPTION  
LDOn Undervoltage interrupt  
(Rising Edge triggered)  
UV_LDOn_EINT  
9:0  
Interrupt Status  
3
Note: Cleared when a ‘1’ is written.  
R16404  
(4014h)  
HC_DC2_EINT  
HC_DC1_EINT  
UV_DCm_EINT  
IM_UV_LDOn_EINT  
DC-DC2 High current interrupt  
(Rising Edge triggered)  
Note: Cleared when a ‘1’ is written.  
DC-DC1 High current interrupt  
(Rising Edge triggered)  
Note: Cleared when a ‘1’ is written.  
DC-DCm Undervoltage interrupt  
(Rising Edge triggered)  
Note: Cleared when a ‘1’ is written.  
Interrupt mask.  
9
Interrupt Status  
4
8
3:0  
9:0  
R16411  
(401Bh)  
0 = Do not mask interrupt.  
1 = Mask interrupt.  
Interrupt Status  
3 Mask  
Default value is 1 (masked)  
Interrupt mask.  
R16412  
(401Ch)  
IM_HC_DC2_EINT  
IM_HC_DC1_EINT  
IM_UV_DCm_EINT  
9
8
0 = Do not mask interrupt.  
1 = Mask interrupt.  
Interrupt Status  
4 Mask  
Default value is 1 (masked)  
Interrupt mask.  
0 = Do not mask interrupt.  
1 = Mask interrupt.  
Default value is 1 (masked)  
Interrupt mask.  
3:0  
0 = Do not mask interrupt.  
1 = Mask interrupt.  
PD, February 2012, Rev 4.0  
86  