 浏览型号WM8321GEFL/RV的Datasheet PDF文件第152页浏览型号WM8321GEFL/RV的Datasheet PDF文件第153页浏览型号WM8321GEFL/RV的Datasheet PDF文件第154页浏览型号WM8321GEFL/RV的Datasheet PDF文件第155页浏览型号WM8321GEFL/RV的Datasheet PDF文件第157页浏览型号WM8321GEFL/RV的Datasheet PDF文件第158页浏览型号WM8321GEFL/RV的Datasheet PDF文件第159页浏览型号WM8321GEFL/RV的Datasheet PDF文件第160页  
WM8321  
Production Data  
REFER TO  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
Thermal Warning interrupt  
TEMP_THW_C  
INT  
1
0
(Rising and Falling Edge triggered)  
Note: Cleared when a ‘1’ is written.  
Register 4011h Interrupt Status 1  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16402  
(4012h)  
Interrupt  
Status 2  
OTP_CMD_EN  
D_EINT  
OTP / ICE Command End interrupt  
(Rising Edge triggered)  
5
0
Note: Cleared when a ‘1’ is written.  
OTP / ICE Command Fail interrupt  
(Rising Edge triggered)  
OTP_ERR_EIN  
T
4
2
1
0
0
0
Note: Cleared when a ‘1’ is written.  
Power On Reset interrupt  
PS_POR_EINT  
(Rising Edge triggered)  
Note: Cleared when a ‘1’ is written.  
PS_SLEEP_O  
FF_EINT  
SLEEP or OFF interrupt (Power state transition to  
SLEEP or OFF states)  
(Rising Edge triggered)  
Note: Cleared when a ‘1’ is written.  
PS_ON_WAKE  
_EINT  
ON or WAKE interrupt (Power state transition to ON  
state)  
0
0
(Rising Edge triggered)  
Note: Cleared when a ‘1’ is written.  
Register 4012h Interrupt Status 2  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16403  
(4013h)  
Interrupt  
Status 3  
UV_LDO10_EI  
NT  
LDO10 Undervoltage interrupt  
(Rising Edge triggered)  
9
0
Note: Cleared when a ‘1’ is written.  
LDO9 Undervoltage interrupt  
(Rising Edge triggered)  
8
7
6
5
4
3
UV_LDO9_EIN  
T
0
0
0
0
0
0
Note: Cleared when a ‘1’ is written.  
LDO8 Undervoltage interrupt  
(Rising Edge triggered)  
UV_LDO8_EIN  
T
Note: Cleared when a ‘1’ is written.  
LDO7 Undervoltage interrupt  
(Rising Edge triggered)  
UV_LDO7_EIN  
T
Note: Cleared when a ‘1’ is written.  
LDO6 Undervoltage interrupt  
(Rising Edge triggered)  
UV_LDO6_EIN  
T
Note: Cleared when a ‘1’ is written.  
LDO5 Undervoltage interrupt  
(Rising Edge triggered)  
UV_LDO5_EIN  
T
Note: Cleared when a ‘1’ is written.  
LDO4 Undervoltage interrupt  
(Rising Edge triggered)  
UV_LDO4_EIN  
T
Note: Cleared when a ‘1’ is written.  