9.6 OVT# interrupt mode  
The OVT# signal is only related with temperature sensor 2.  
9.6.1 The W83697HF temperature sensor 2 Over-Temperature (OVT#) has the following  
modes  
(1) Comparator Mode(Default):  
Setting Bank1/2 CR[52h] bit 2 to 0 will set OVT# signal to comparator mode. Temperature  
exceeding T causes the OVT# output activated until the temperature is less than THYST. ( Figure  
O
9.12)  
(2) Interrupt Mode:  
Setting Bank1/2 CR[52h] bit 2 to 1 will set OVT# signal to interrupt mode. Setting Temperature  
exceeding T causes the OVT# output activated indefinitely until reset by reading temperature  
O
sensor 2 or sensor 3 registers. Temperature exceeding T , then OVT# reset, and then temperature  
O
going below THYST will also cause the OVT# activated indefinitely until reset by reading temperature  
sensor2 or sensor 3 registers. Once the OVT# is activated by exceeding T , then reset, if the  
O
temperature remains above THYST , the OVT# will not be activated again.( Figure 9.12)  
Temperature sensor 2 and 3 Over-Temperature output (OVT#) in ACPI mode  
Setting CR[4Ch] bit 1 to 1 will set OVT# signal to ACPI mode. At this mode, temperature exceeding  
one level of temperature separation, starting from 0 degree, causes the OVT# output activated.  
OVT# will be activated again once temperature exceeding the next level. OVT# output will act the  
same manner when temperature goes down. (Figure 17,18). If temperature goes around the  
current level, the OVT# will not act.(Refer the arrow in the figure). The granularity of temperature  
separation between each OVT# output signal can be programmed at Bank0 CR[5Fh].  
The priority of this mode is higher than Comparator mode and Interrupt mode .  
Publication Release Date: Feb. 2002  
- 94 -  
Revision 0.70  
 复制成功!