W83697HF/F  
9.5.4 The W83697HF temperature sensor 2 SMI# interrupt has two modes and it is programmed  
at CR[4Ch] bit 6.  
(1) Comparator Interrupt Mode:  
Temperature exceeding T causes an interrupt and this interrupt will be reset by reading all the  
O
Interrupt Status Register. Once an interrupt event has occurred by exceeding T , then reset, if the  
O
temperature remains above the THYST, the interrupt will occur again when the next conversion has  
completed. If an interrupt event has occurred by exceeding TO and not reset, the interrupts will not  
occur again. The interrupts will continue to occur in this manner until the temperature goes below  
T
HYST  
.
( Figure 9.10 )  
(2) Two-Times Interrupt Mode(Default):  
Temperature exceeding T causes an interrupt and then temperature going below THYST will also  
O
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status  
Register. Once an interrupt event has occurred by exceeding T , then reset, if the temperature  
O
remains above the THYST , the interrupt will not occur. (Figure 9.11 )  
T
OI  
T
OI  
T
HYST  
T
HYST  
SMI#  
SMI#  
*
*
*
*
*
*
*
*
*Interrupt Reset when Interrupt Status Registers are read  
Figure 9.10  
Figure 9.11  
Publication Release Date: Feb. 2002  
Revision 0.70  
- 93 -  