Preliminary W27C4096
READ OPERATION DC CHARACTERISTICS
(VCC = 5.0V ±5%, TA = 0 to 50° C)
PARAMETER
SYM.
CONDITIONS
LIMITS
UNIT
MIN.
TYP.
MAX.
5
Input Load Current
ILI
VIN = 0V to VCC
-5
-
-
mA
mA
Output Leakage Current
VCC Standby Current
ILO
ISB
ISB1
ICC
VOUT = 0V to VCC
-10
10
-
-
-
-
1.0
100
30
mA
CE = VIH
5
-
mA
CE = VCC ±0.2V
VCC Operating Current
mA
CE = VIL
IOUT = 0 mA, f = 5 MHz
VPP Operating Current
Input Low Voltage
IPP
VPP = VCC
-
-0.3
2.2
-
-
-
-
-
-
10
0.8
mA
V
VIL
-
Input High Voltage
Output Low Voltage
Output High Voltage
VPP Operating Voltage
VIH
VOL
VOH
VPP
-
IOL = 2.1 mA
IOH = -0.4 mA
-
VCC +0.5
0.4
V
-
V
2.4
-
V
VCC -0.7
VCC
V
READ OPERATION AC CHARACTERISTICS
(VCC = 5.0V ±5%, TA = 0 to 50° C)
PARAMETER
SYM.
W27C4096-12
W27C4096-15
UNIT
MIN.
MAX.
-
MIN.
MAX.
-
Read Cycle Time
TRC
TCE
TACC
TOE
TDF
120
150
nS
nS
nS
nS
nS
Chip Enable Access Time
Address Access Time
-
-
-
-
120
120
50
-
-
-
-
150
150
70
Output Enable Access Time
30
30
OE High to High-Z Output
Output Hold from Address Change
TOH
0
-
0
-
nS
Note: VCC must be applied simultaneously or before VPP and removed simultaneously or after VPP.
- 6 -