TABLE I. Electrical performance characteristics.
Test
Symbol
Conditions 1/ 2/
-55°C ≤ TC ≤ +125°C
Group A
subgroups
Device
types
Limits
Unit
Min
Max
VSS = 0 V dc
+4.5 V dc ≤ VCC ≤ +5.5 V dc
unless otherwise specified
DC parameters
Operating supply current
ICC
CS = VIH, OE = VIH,
VCC = 5.5 V dc
3/
mA
1,2,3
01-04
05-16
200
600
f = 5 MHz
f = 5 MHz
05,11
06,12
07,13
08,14
09,15
10,16
17,19
625
635
650
675
725
750
200
f = 18.2 MHz
f = 22.2 MHz
f = 28.6 MHz
f = 40 MHz
f = 50 MHz
f = 58.8 MHz
f = 66.67 MHz
f = 83.3 MHz
18,20
250
Standby current
ISB
CS = VIH, OE = VIH,
VCC = 5.5 V dc
3/
f = 5 MHz
f = 5 MHz
1,2,3
01-04
05-16
4
80
mA
f = 18.2 MHz
f = 22.2 MHz
f = 28.6 MHz
f = 40 MHz
05,11
06,12
07,13
08,14
09,15
10,16
17-20
17-20
150
150
190
240
280
320
80
f = 50 MHz
f = 58.8 MHz
f = 66.67 MHz
f = 83.3 MHz
80
Input leakage current
Output leakage current
ILI
VCC = 5.5 V dc,
VIN = GND or VCC
1,2,3
1,2,3
All
10
10
µA
µA
ILO
All
CS = VIH, OE = VIH,
VIN = GND or VCC
Output low voltage
VOL
V
CC = +4.5 V dc,
1,2,3
01-06,
11,12
0.4
0.4
V
I
OL = 2.1 mA
VCC = +4.5 V dc,
OL = 6 mA
07-10,
13-20
I
Output high voltage
VOH
V
CC = +4.5 V dc,
1,2,3
01-06,
11,12
2.4
2.4
V
I
OH = -1.0 mA
VCC = +4.5 V dc,
07-10,
13-20
I
OH = -4.0 mA
See footnotes at end of table.
SIZE
STANDARD
MICROCIRCUIT DRAWING
5962-94611
A
REVISION LEVEL
SHEET
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
6
R
DSCC FORM 2234
APR 97