 浏览型号CG24S51-5000-RC的Datasheet PDF文件第1页浏览型号CG24S51-5000-RC的Datasheet PDF文件第2页浏览型号CG24S51-5000-RC的Datasheet PDF文件第3页浏览型号CG24S51-5000-RC的Datasheet PDF文件第4页浏览型号CG24S51-5000-RC的Datasheet PDF文件第5页浏览型号CG24S51-5000-RC的Datasheet PDF文件第7页浏览型号CG24S51-5000-RC的Datasheet PDF文件第8页浏览型号CG24S51-5000-RC的Datasheet PDF文件第9页  
CG Series  
Single Output  
2:1 Input Voltage Range  
30 Watt DC/DC Converter  
Rev B  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source  
impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and output loading is high, it may be necessary  
to use a capacitor at the input to ensure startup.  
A capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to  
use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of 10uF for the  
24V and 48V input devices.  
Maximum Capacitive Load  
The CG Series has a limitation of maximum connected capacitance at the output. The power module  
may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time.  
The maximum capacitance can be found in the “Output Voltage / Current Rating Chart.”  
Over Current Protection  
To provide protection in a fault (output overload) condition, the unit is equipped with internal current  
limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit  
inception, the unit shifts from voltage control to current control. The unit operates normally once the  
output current is brought back into its specified range.  
Output Over Voltage Protection  
The output over voltage clamp consists of control circuitry, which is independent of the primary  
regulation loop that monitors the voltage on the output terminals. The control loop of the clamp has a  
higher voltage set point than the primary loop. This provides a redundant voltage control that reduces  
the risk of output over voltage. The OVP level can be found in the “Output Voltage / Current Rating  
Chart.”  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over  
the module, and board spacing. To avoid exceeding the maximum temperature rating of the components  
inside the power module, the case temperature must be kept below 105°C. The derating curves are  
determined from measurements obtained in an experimental apparatus.  
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
5/15/2019  
Page 6 of 9