CG Series
Single Output
2:1 Input Voltage Range
30 Watt DC/DC Converter
Rev B
SPECIFICATION
GENERAL
TEST CONDITIONS
Min
Nom
Max
Unit
Efficiency
See Table
Switching Frequency
Isolation Voltage Rated
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Internal Power Dissipation
ENVIRONMENTAL
Operating Temperature (Ambient)
Operating Temperature (Case)
Storage Temperature
Lead Temperature
Humidity
280
350
400
KHz
VDC
VDC
MΩ
pF
mW
60 seconds
Flash Tested for 1 second
500VDC
1500
1650
1000
100KHz, 1V
1200
1500
5500
-40
-40
-55
+50
+105
+125
260
°C
°C
°C
°C
%
1.5mm from case for 10 seconds
95
Cooling
Free air convection
RFI
MTBF
Six-sided shielded metal case
600,000 Hours
MIL-HDBK-217F @ 25°C, Ground Benign
Conducted EMI
PHYSICAL
EN55022 Class A
Weight
32 grams
Dimensions
Case Material
50.8(L) x 25.4(W) x 10.2(H) mm
Aluminum anodizing treatment in black
OUTPUT VOLTAGE / CURRENT RATING CHART
Output Current
Input Current
Output
Reflected
Ripple Current Protection
Over Voltage Max Capacitive Efficiency
Model Number Input Voltage
Voltage
Load
(Typ)
Min
Max
No Load Max Load
CG24S2.5-6000
CG24S3.3-6000
2.5 VDC
3.3 VDC
5 VDC
0mA
6000mA
50mA
50mA
70mA
70mA
20mA
20mA
40mA
40mA
50mA
50mA
10mA
10mA
744mA
959mA
1185mA
1207mA
1420mA
1420mA
372mA
480mA
604mA
604mA
710mA
710mA
3 VDC
6800μF
84%
0mA
0mA
0mA
6000mA
5000mA
5000mA
2500mA
2000mA
6000mA
6000mA
5000mA
5000mA
2500mA
2000mA
3.9 VDC
6800μF
6800μF
6800μF
680μF
86%
88%
88%
88%
88%
84%
86%
88%
88%
88%
88%
CG24S5-5000
CG24S5.1-5000
CG24S12-2500
CG24S15-2000
CG48S2.5-6000
CG48S3.3-6000
CG48S5-5000
CG48S5.1-5000
CG48S12-2500
CG48S15-2000
6.8 VDC
100mA (typ)
24 VDC
(18 – 36 VDC)
5.1 VDC
6.8 VDC
12 VDC 166mA
15 VDC 133mA
15 VDC
18 VDC
3 VDC
680μF
2.5 VDC
3.3 VDC
5 VDC
0mA
0mA
0mA
0mA
6800μF
6800μF
6800μF
6800μF
680μF
3.9 VDC
6.8 VDC
50mA (typ)
48 VDC
(36 – 75 VDC)
5.1 VDC
6.8 VDC
12 VDC 166mA
15 VDC 133mA
15 VDC
18 VDC
680μF
NOTES
1. Specifications typical at +25°C, resistive load, nominal input voltage, rated output current unless otherwise noted.
2. Transient Recovery Time is measured to within 1% error band for a step change in output load of 75% to 100%.
3. Ripple & Noise measurement bandwidth is 0- 20MHz.
4. These power converters require a minimum output loading to maintain specified regulation. Operation at no-load
will not damage these devices, however they may not meet all listed specifications.
5. All DC/DC converters should be externally fused at the front end for protection.
6. Other input and output voltages may be available, please contact factory.
7. Specifications subject to change without notice.
8. To order the converter with Remote On/Off function, please add suffix ”-RC” (Ex: CG48S5-5000(A)-RC).
Due to advances in technology, specifications subject to change without notice.
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website: www.wallindustries.com • e-mail: sales@wallindustries.com