欢迎访问ic37.com |
会员登录 免费注册
发布采购

SCA3000-E05-1 参数 Datasheet PDF下载

SCA3000-E05-1图片预览
型号: SCA3000-E05-1
PDF下载: 下载PDF文件 查看货源
内容描述: [Analog Circuit]
分类和应用:
文件页数/大小: 45 页 / 1038 K
品牌: VTI [ VTI TECHNOLOGIES ]
 浏览型号SCA3000-E05-1的Datasheet PDF文件第18页浏览型号SCA3000-E05-1的Datasheet PDF文件第19页浏览型号SCA3000-E05-1的Datasheet PDF文件第20页浏览型号SCA3000-E05-1的Datasheet PDF文件第21页浏览型号SCA3000-E05-1的Datasheet PDF文件第23页浏览型号SCA3000-E05-1的Datasheet PDF文件第24页浏览型号SCA3000-E05-1的Datasheet PDF文件第25页浏览型号SCA3000-E05-1的Datasheet PDF文件第26页  
SCA3000 Series  
Address value: 00001  
Register name: I2C_DISABLE, disable I2C communication, only for SCA3000-D03 and  
SCA3000-L01 (Indirect access via CTRL_SEL)  
Initial  
Value  
0x10  
Bits  
7:0  
Name  
Description  
I2C_DIS  
For SCA3000-D03:  
0x10 – I2C enabled, default value after start up  
0x00 – I2C disabled  
7:0  
0x50  
I2C_DIS  
For SCA3000-L01:  
0x50 – I2C enabled, default value after start up  
0x40 – I2C disabled  
See section 4.1.4 for more detailed information of disabling the I2C communication.  
Address value: 00010  
Register name: MD_CTRL, Motion Detector control (Indirect access via CTRL_SEL)  
Initial  
Value  
Bits  
Name  
Description  
Reserved  
Note  
7:6  
5
0
0
0
REQ_Z  
REQ_X  
REQ_Y  
1 – Require trigger on Z-channel Bits 5:3 can be  
0 – Not required used to build logical  
1 – Require trigger on X-channel AND operation  
0 – Not required between channels.  
1 – Require trigger on Y-channel Example:  
4
3
0 – Not required  
X and Y = Require  
X and Y, ignore Z  
00 011 011  
2
1
0
1
1
1
EN_Z  
EN_X  
EN_Y  
1 – Enable trigger on Z-channel  
0 – Not required  
1 – Enable trigger on X-channel  
0 – Not required  
1 – Enable trigger on Y-channel  
0 – Not required  
Bits 2:0 can be  
used to build logical  
OR operation  
between channels.  
Example:  
X or Y = Disable Z  
00 000 011  
Address value: 00011  
Register name: MD_Y_TH, Motion Detector Y-threshold (Indirect access via CTRL_SEL)  
Initial  
Value  
10h or 08h  
Bits  
7:0  
Name  
Y_TH  
Description  
Threshold for Y-acceleration change when MD  
is used.  
Address value: 00100  
Register name: MD_X_TH, Motion Detector X-threshold (Indirect access via CTRL_SEL)  
Initial  
Value  
10h or 08h  
Bits  
7:0  
Name  
X_TH  
Description  
Threshold for X-acceleration change when MD  
is used.  
Address value: 00101  
Register name: MD_Z_TH, Motion Detector Z-threshold (Indirect access via CTRL_SEL)  
Initial  
Value  
10h or 08h  
Bits  
7:0  
Name  
Z_TH  
Description  
Threshold for Z-acceleration change when MD is  
used.  
VTI Technologies Oy  
www.vti.fi  
PRELIMINARY - Subject to changes  
Doc.Nr. 8257300A.06  
22/ 45  
Rev.A.06  
 复制成功!