SCA8X0/21X0/3100 Series  
2.4 Power Down mode  
For low power applications it is possible to set the accelerometer into power down mode. During  
the power down mode the power consumption is minimized inside the device. This is achieved by  
stopping the internal clocks and resetting the control registers of the device. Please refer to the  
individual device data sheets for detail power consumption figures.  
2.5 Recommended start-up sequence  
For correct device operation there are no specific configuration needed for the device before  
starting of measuring the acceleration. However if the device detail features are being used the  
following operations could be made after the powering on the device.  
Table 2: SCA8X0 start up sequence  
Item  
1
Procedure  
Set Vdd=3.0...3.6V  
Functions  
Check  
-
Set the  
power on to  
release part  
from reset  
and to start  
the operation  
During the  
first 95ms the  
part is  
2
Wait 95ms  
-
performing  
the memory  
read and self-  
diagnostics.  
Possible  
signal path  
self-  
diagnostic  
test is carried  
out.  
Settling of  
signal path  
Check the  
self-test pass  
status  
Check the  
memory  
checksum  
pass status  
3
4
Read CTRL-register  
CTRL.ST=0  
SPI fixed bits  
dPAR, data parity  
STATUS.CSMERR=0  
SPI fixed bits  
SPI FRME=0  
dPAR, data parity  
SPI fixed bits  
Read STATUS-register  
5
Write CTRL=0000 0000  
After device  
power on set  
PORST=0 to  
be able to  
detect any  
future  
SPI FRME=0  
occurring  
power  
failures  
6
Read X_MSB, X_LSB –  
registers  
Start reading  
the  
acceleration  
data  
SPI fixed bits  
SPI FRME=0  
SPI PORST=0  
dPAR, data parity  
VTI Technologies Oy  
www.vti.fi  
9/35  
Doc. Nr. 82 694 00 C  