欢迎访问ic37.com |
会员登录 免费注册
发布采购

CMA3000-D01-10 参数 Datasheet PDF下载

CMA3000-D01-10图片预览
型号: CMA3000-D01-10
PDF下载: 下载PDF文件 查看货源
内容描述: 3轴加速度计 [3-axis accelerometer]
分类和应用:
文件页数/大小: 35 页 / 945 K
品牌: VTI [ VTI TECHNOLOGIES ]
 浏览型号CMA3000-D01-10的Datasheet PDF文件第22页浏览型号CMA3000-D01-10的Datasheet PDF文件第23页浏览型号CMA3000-D01-10的Datasheet PDF文件第24页浏览型号CMA3000-D01-10的Datasheet PDF文件第25页浏览型号CMA3000-D01-10的Datasheet PDF文件第27页浏览型号CMA3000-D01-10的Datasheet PDF文件第28页浏览型号CMA3000-D01-10的Datasheet PDF文件第29页浏览型号CMA3000-D01-10的Datasheet PDF文件第30页  
CMA3000-D0X Series  
8
Data sheet references  
8.1 Offset  
CMA3000's offset will be calibrated in X = 0 g, Y = 0 g, and Z = +1 g (Z measuring axis is parallel to  
earth’s gravitation) position, see Figure 18.  
Z-axis in +1 g  
position  
Earth’s  
gravitation  
Y
X
Pin #1  
Figure 18. CMA3000 offset (0 g) position.  
8.1.1 Offset calibration error  
Offset calibration error is the difference between the sensor's actual output reading and the nominal  
output reading in calibration conditions. Error is calculated by  
Equation 1  
OutputX axis Output  
OffsetX axisCalibEr  
=
1000,  
Sens  
where OutputX-axisCalibEr is sensor’s X-axis calibration error in [mg], OutputX-axis is sensor’s X-axis  
output reading [counts], Output is sensor’s nominal output in 0 g position and Sens sensor’s nominal  
sensitivity [counts/g].  
8.1.2 Offset temperature error  
Offset temperature error is the difference between the sensor's output reading in different  
temperatures and the sensor’s calibrated offset value at room temperature. Error is calculated by  
Equation 2  
OutputX axis @T OutputX axis @ RT  
OffsetX axisTempEr @T  
=
1000,  
Sens  
where OutputX-axisTempEr@T is sensor’s X-axis temperature error in [mg] in temperature T, OutputX-axis@T  
is sensor’s X-axis output reading [counts] in temperature T, OutputX-axis@T X-axis output reading  
[counts] at room temperature RT and Sens sensor’s nominal sensitivity [counts/g]. Sensor is in 0 g  
position for every measurement point.  
8.2 Sensitivity  
During sensitivity calibration, the sensor is placed in ±1 g positions having one of the sensor’s  
measuring axes at a time parallel to the earth’s gravitation, see Figure 19.  
VTI Technologies Oy  
www.vti.fi  
26/ 35  
Rev. 0.12  
Doc.Nr. 8281000.12