DG417L/418L/419L
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 5 V)
Test Conditions
Unless Specified
Parameter
Symbol
V+ = 5 V, V - = 0 V
V
L
= 5 V, V
IN
= 2.4 V, 0.8 V
f
A Suffix Limits
-55 to 125_C
D Suffix Limits
-40 to 85_C
Temp
b
Room
Full
Room
Full
Room
Room
Typ
c
37
16
19
0.4
Min
d
Max
d
49
60
31
35
Min
d
Max
d
49
54
31
32
Unit
Dynamic Characteristics
Turn-On Time
e
Turn-Off Time
e
Break-Before-Make
Time Delay
e
Charge Injection
e
t
ON
t
OFF
t
D
Q
INJ
R
L
= 300
W
, C
L
= 35 pF
V
NO
, V
NC
= 3.5 V, See Figure 2
DG419L Only, V
NO
, V
NC
= 3.5 V
R
L
= 300
W
, C
L
= 35 pF
V
g
= 0 V, R
g
= 0
W
, C
L
= 1 nF
ns
pC
Power Supplies
Positive Supply Current
e
Negative Supply
Current
e
Logic Supply Current
e
Ground Current
e
I+
I-
V
IN
= 0 or V
L
I
L
I
GND
Room
Full
Room
Full
Room
Full
Room
Full
0.02
-0.002
0.002
-0.002
-1
-7.5
-1
-7.5
1
7.5
-1
-5
1
7.5
-1
-5
1
5
1
5
mA
SPECIFICATIONS (SINGLE SUPPLY 3 V)
Test Conditions
Unless Specified
Parameter
Analog Switch
Analog Signal Range
e
On-Resistance
V
ANALOG
r
ON
I
NO(off),
I
NC(off)
I
COM(off)
I
COM(on)
V+ = 2.7 V, V - = 0 V
I
NO
, I
NC
= 5 mA, V
COM
= 0.5, 2.2 V
V+ = 3.3 V, V - = 0 V
V
COM
= 1, 2 V, V
NO
, V
NC
= 2, 1 V
V+ = 3.3 V, V - = 0 V
V
NO
, V
NC
= V
COM
= 1, 2 V
Full
Room
Full
Room
Full
Room
Full
Room
Full
47
-1
-15
-1
-15
-1
-15
0
3
70
80
1
15
1
15
1
15
-1
-10
-1
-10
-1
-10
0
3
70
75
1
10
1
10
1
10
nA
V
W
A Suffix Limits
-55 to 125_C
D SuffixLimits
-40 to 85_C
Symbol
V+ = 3 V, V - = 0 V
V
L
= 3 V, V
IN
= 2.0 V, 0.4 V
f
Temp
b
Typ
c
Min
d
Max
d
Min
d
Max
d
Unit
Switch Off
Leakage Current
a
Channel On
Leakage Current
a
Digital Control
Input Current
a
I
INL
or I
INH
Full
0.005
-1.5
1.5
-1
1
mA
Dynamic Characteristics
Turn-On Time
Turn-Off Time
Break-Before-Make
Time Delay
Charge Injection
e
Off
Isolation
e
Channel-to-Channel
Crosstalk
e
Source Off Capacitance
e
Channel On Capacitance
e
t
ON
t
OFF
t
D
Q
INJ
OIRR
X
TALK
C
NO(off),
C
NC(off)
C
D(on)
R
L
= 300
W
, C
L
= 35 pF
V
NO
, V
NC
= 1.5 V See Figure 2
DG419L Only, V
NO
, V
NC
= 1.5 V
R
L
= 300
W
, C
L
= 35 pF
V
g
= 0 V, R
g
= 0
W
, C
L
= 1 nF
R
L
= 50
W
, C
L
= 5 pF
f = 1 MHz
Room
Full
Room
Full
Room
Room
Room
Room
Room
f = 1 MHz
Room
16
65
26
33
1
-71
-77
5.6
pF
dB
pC
75
95
41
45
75
85
41
43
ns
Notes:
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f.
V
IN
= input voltage to perform proper function.
www.vishay.com
Document Number: 71763
S-03423—Rev. C, 03-Mar-03
4