V23990-P541-A21/ C21-PM
final datasheet
flow PIM 0
6A / 600V
Output inverter
Figure 5. Typical switching energy losses
Figure 6. Typical switching energy losses
as a function of gate resistor
as a function of collector current
Output inverter IGBT
E = f (Ic)
Output inverter IGBT
E = f (RG)
0,35
0,3
0,35
0,3
Eon
Eoff
0,25
0,2
0,25
0,2
Eoff
Eon
0,15
0,1
0,15
0,1
Erec
Erec
0,05
0
0,05
0
R G ( ꢁ )
300
I C (A)
0
2
4
6
8
10
12
0
60
120
180
240
inductive load, Tj = 125 °C
VCE = 300 V
inductive load, Tj = 125 °C
VCE = 300 V
VGE=
Rgon=
Rgoff=
15 V
32 ꢃ
16 ꢃ
VGE=
Ic =
15 V
6 A
Figure 7. Typical switching times as a
function of collector current
Figure 8. Typical switching times as a
function of gate resistor
Output inverter IGBT
Output inverter IGBT
t = f (Ic)
t = f (RG)
1
1
tdoff
tdoff
0,1
0,1
tf
tf
tdon
tr
tdon
0,01
0,01
tr
0,001
0,001
0
2
4
6
8
10
12
IC (A)
0
60
120
180
240
300
R G ( ꢁ )
inductive load, Tj = 125 °C
VCE = 300 V
inductive load, Tj = 125 °C
VCE = 300 V
VGE=
Rgon=
Rgoff=
15 V
32 ꢃ
16 ꢃ
VGE=
Ic =
15 V
6 A
Copyright by Vincotech
Revision: 1
Revision: 1
copyright Tyco Electronics
2