Electrical Characteristics, continued
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
AC Bus OK (B OK)
On-state resistance (low)
15
-50
Ω
To negative output - bus normal
Bus normal
On-state current (low)
Off-state voltage
mA
Vdc
Vdc
Vdc
14.8
235
200
15.0
240
205
15.2
245
210
Bus abnormal, 27K internal pull up to 15Vdc (Fig. 10)
Output bus voltage
On-state threshold
Off-state threshold
Output bus voltage
Module Enable (EN)
On-state resistance (low)
15
50
Ω
To negative output - converters are disabled
On-state current (low)
Off-state voltage
mA
Vdc
Vdc
Vdc
Vdc
Vdc
14.8
235
200
380
15.0
240
205
390
17
15.2
245
210
400
20
150K internal pull up to 15Vdc (Fig. 9)
Output bus voltage
On-state threshold
Off-state threshold
Output bus voltage
Over voltage shutdown
AC Bus OK - module enable, differential error* 15
AC Bus OK and module enable thresholds track
* Tracking error between BUS OK and Enable thresholds
MODULE GENERAL SPECIFICATIONS
Parameter
MTBF
Min
Typ
Max
Unit
hours
Notes
>1,000,000
25˚C, ground benign
Aluminum
Baseplate material
Cover
Polyetherimide
Pin material
Weight
Copper, tin/lead solder dipped
2.1 (60)
ounces (grams)
2.28 x 1.45 x 0.5
(57,9 x 36,8 x 12,7)
inches
(mm)
Size
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
ARM, Autoranging Rectifier Module
Rev. 2.4
Page 3 of 12
Set your site on VICOR at www.vicorpower.com